background image

 

308175T

EN

Instructions - Parts

AIR-DRIVEN

Twistork

®

 Helix 

Agitator

Air driven agitator for mixing and maintaining suspension of industrial coatings. 
For professional use only.

100 psi (0.7 MPa, 7 bar) Maximum Working Pressure

See page 2 for model information.

Important Safety Instructions

Read all warnings and instructions in this 
manual before using the equipment. 
Save these instructions.

2575

II 1/2 G Ex h IIB T3 Ga/Gb
ITS03ATEX11226X
ITS21UKEX0224X

0359

Summary of Contents for Twistork 224854

Page 1: ...industrial coatings For professional use only 100 psi 0 7 MPa 7 bar Maximum Working Pressure See page 2 for model information Important Safety Instructions Read all warnings and instructions in this...

Page 2: ...7 Check Fluid Viscosity 7 Maintenance 8 Flush the Air Motor 8 Agitator Blades 8 Lubricate the Air Motor 8 Service 9 Align the Outlet Housing 9 Parts 10 Model 224854 Twistork Helix Agitator 10 Model 23...

Page 3: ...and gasoline Do not plug or unplug power cords or turn power or light switches on or off when flammable fumes are present Use only grounded hoses Hold gun firmly to side of grounded pail when triggeri...

Page 4: ...y approvals and create safety hazards Make sure all equipment is rated and approved for the environment in which you are using it Use equipment only for its intended purpose Call your distributor for...

Page 5: ...t numbers listed below 110223 1 4 npt f x 1 4 npt f 110224 3 8 npt f x 3 8 npt f 113333 3 8 npt m x 3 8 npt f Install an air line filter AF to remove harmful dirt and moisture from the air supply To o...

Page 6: ...rical code for detailed grounding instructions for your area and type of equipment Remove the grounding screw A and lockwasher B See FIG 3 Secure the ground wire terminal C to the agitator with the sc...

Page 7: ...d possible To stop the agitator close the bleed type air shutoff valve SV or close the needle valve 11 Stop the agitator and disconnect the air line before removing it from the container Check Fluid V...

Page 8: ...rease the material conductivity with additives Use liquids with a high conductivity 1000 pS m Lubricate the Air Motor If an air line lubricator AL is not installed the air motor must be manually lubri...

Page 9: ...the following Replacing the outlet housing 4 Replacing the air motor 1 Repairing the agitator 1 Place the agitator in a vertical position and loosen the three outlet housing screws 17 See Parts page 1...

Page 10: ...ue to 80 100 in lbs 9 11 3 N m 1 2 Apply medium grade sealant to external threads Torque to 34 40 in lbs 4 4 5 N m Be sure air motor shaft bottoms out in mounting hole before tightening 3 Align as ins...

Page 11: ...ch 1 2 20 X 0 5 3 4 224876 HOUSING outlet carbon steel 1 6 224393 HELIX agitator 1 7 187054 PLUG fluid tube 1 8 101946 PIN cotter 1 9 111312 O RING Fluoroelastomer 1 10 112364 SCREW set socket 1 4 20...

Page 12: ...que to 80 100 in lbs 9 11 3 N m 1 2 Apply medium grade sealant to external threads Torque to 34 40 in lbs 4 4 5 N m Be sure air motor shaft bottoms out in mounting hole before tightening 3 Align as in...

Page 13: ...HOUSING outlet carbon steel 1 6 224393 HELIX agitator 1 7 187054 PLUG fluid tube 1 8 101946 PIN cotter 1 9 111312 O RING Fluoroelastomer 1 10 112364 SCREW set socket 1 4 20 UNC 3A 2 11 206264 VALVE n...

Page 14: ...Dimensions 14 308175T Dimensions 6 96 in 177 mm To bottom of threads 1 8 npt 2 11 1 2 npt 32 67 in 830 mm 0908C...

Page 15: ...104 F 1 C Ta 40 C Wetted Parts Model 224854 Carbon Steel Fluoroelastomer Acetal Model 235534 304 316 Stainless Steel Fluoroelastomer Acetal Noise dBa Pressure Power Noise level at 100 psi normal load...

Page 16: ...n material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRA...