Instructions/Parts
In-Line Filters and Coalescers
with Automatic Drains
310611G
EN
Air Filter with Automatic Drain
Part No. 22601, Series B
Maintenance
To maintain maximum filtering efficiency and to
avoid excessive pressure drop, the filter must be
kept clean. Bowl drainage is automatic with the
float drain. Remove the bowl to drain manually. A
visible coating of dirt on the filter element surface or
an excessive pressure drop is an indication that
cleaning is necessary.
Cleaning
To clean, it is not necessary to remove the com-
plete filter from the line. Disassembly is simple and
does not require tools. Before disassembly, shut off
the air supply and depressurize filter. Clean all
parts with cleaning solvent and blow out filter body
before reassembly. Wash filter element in cleaning
solvent and blow out from the inside.
Automatic Drain
The Automatic drain is equipped with a float actu-
ated device which automatically ejects liquid con-
taminates under pressure.
Specifications
Air Inlet 1/2 in. F.P.T.
Air Outlet 1/2 in. F.P.T.
Air Flow Capacity 100 cfm (3.2 m
3
/min.) at 100 psi
(0.7 MPa, 7 bar)
Max. Operating Pressure 175 psi (1.2 MPa, 12 bar)
Max. Temperature 150°F (65°C)
Parts (Series B)
Part No.
Description
24U115
Automatic Drain
127289
O-Ring
16W811
Baffle End Cap
16W405
Filter Element
O-Ring
Filter Element
Automatic
Drain
(127289)
(16W405)
(24U115)
Baffle End Cap
(16W811)
ti22164a
Important Safety Instructions
Read all warnings and instructions in your
equipment manual. Save all instructions.