background image

Instructions/Parts

In-Line Filters and Coalescers
with Automatic Drains

310611G

EN

Air Filter with Automatic Drain

Part No. 22601, Series B

Maintenance

To maintain maximum filtering efficiency and to 
avoid excessive pressure drop, the filter must be 
kept clean. Bowl drainage is automatic with the 
float drain. Remove the bowl to drain manually. A 
visible coating of dirt on the filter element surface or 
an excessive pressure drop is an indication that 
cleaning is necessary.

Cleaning

To clean, it is not necessary to remove the com-
plete filter from the line. Disassembly is simple and 
does not require tools. Before disassembly, shut off 
the air supply and depressurize filter. Clean all 
parts with cleaning solvent and blow out filter body 
before reassembly. Wash filter element in cleaning 
solvent and blow out from the inside.

Automatic Drain

The Automatic drain is equipped with a float actu-
ated device which automatically ejects liquid con-
taminates under pressure.

Specifications

Air Inlet 1/2 in. F.P.T.
Air Outlet 1/2 in. F.P.T.
Air Flow Capacity 100 cfm (3.2 m

3

/min.) at 100 psi 

(0.7 MPa, 7 bar)

Max. Operating Pressure 175 psi (1.2 MPa, 12 bar)
Max. Temperature 150°F (65°C)

Parts (Series B)

Part No.

Description

24U115

Automatic Drain

127289

O-Ring

16W811

Baffle End Cap