Startup
309551C
27
If FTS is disconnected or display shows
diagnostic code E04, turn main power
switch OFF
then ON
to clear diagnostic code and enter man-
ual current control mode.
display
will show current to hose. Current is not
limited by target temperature.
To prevent overheating, install hose
thermometer close to gun end, within
operator view. Insert thermometer
through foam cover of A component
hose so stem is next to inner tube.
Thermometer reading will be about
20°F less than actual fluid temperature.
If thermometer reading exceeds 160°F
(71°C), reduce current with
key.
h.
Manual current control mode only:
WARNING
Read warnings, page 5. When in manual current con-
trol mode, monitor hose temperature with thermome-
ter. Install per instructions below. Thermometer
reading must not exceed 160°F (71°C).
3.
Set pressure
a.
Press .
b.
Press motor
. Motor and pumps
start. Display shows system pressure.
Motor runs until setpoint reached.
c.
Press
or
until display
shows desired fluid pressure. Display
will show setpoint for 10 sec, then
change to actual pressure.
If display pressure is greater than setpoint pres-
sure, trigger gun to reduce pressure.
If display shows J xx, unit is in jog mode. To exit
jog mode, see page 34.
d.
To display cycle count, press
.
To clear counter, press and hold
for 3 sec.
e.
Press
or
to change pres-
sure scale.
PSI
BAR