background image

Models

312067H

3

Models

E-20 SERIES

E-30 SERIES

E-XP1 SERIES

E-XP2 SERIES

* Full load amps with all devices operating at maximum capabilities. Fuse requirements at various flow rates and mix 

chamber sizes may be less.

 Total system watts, based on maximum hose length for each unit:

E-20 and E-XP1 series, 210 ft (64 m) maximum heated hose length, including whip hose.

E-30 and E-XP2 series, 310 ft (94.5 m) maximum heated hose length, including whip hose.

 Maximum flow rate given for 60 Hz operation. For 50 Hz operation, maximum flow rate is 5/6 of 60 Hz maximum 

flow.

Part, Series

Full Load Peak 
Amps*

Nominal Voltage 
Range (phase)

System 
Watts†

Primary 
Heater 
Watts

Max Flow 
Rate

lb/min 
(kg/min)

Approximate 
Output per Cycle 
(A+B)
gal. (liter)

Maximum Fluid 
Working Pressure 
psi (MPa, bar)

259025, G

48

200-240 V (1)

10,200

6,000

20 (9)

0.0104 (0.0395)

2000 (14, 140)

259030, G

24

350-415 V (3)

10,200

6,000

20 (9)

0.0104 (0.0395)

2000 (14, 140)

259034, G

32

200-240 V (3)

10,200

6,000

20 (9)

0.0104 (0.0395)

2000 (14, 140)

Part, Series

Full Load Peak 
Amps*

Nominal Voltage 
Range (phase)

System 
Watts†

Primary 
Heater 
Watts

Max Flow 
Rate

lb/min 
(kg/min)

Approximate 
Output per Cycle 
(A+B)
gal. (liter)

Maximum Fluid 
Working Pressure 
psi (MPa, bar)

259026, F

78

200-240 V (1)

17,900

10,200

30 (13.5)

0.0272 (0.1034)

2000 (14, 140)

259031, F

34

350-415 V (3)

17,900

10,200

30 (13.5)

0.0272 (0.1034)

2000 (14, 140)

259035, F

50

200-240 V (3)

17,900

10,200

30 (13.5)

0.0272 (0.1034)

2000 (14, 140)

259057, F

100

200-240 V (1)

23,000

15,300

30 (13.5)

0.0272 (0.1034)

2000 (14, 140)

259058, F

62

200-240 V (3)

23,000

15,300

30 (13.5)

0.0272 (0.1034)

2000 (14, 140)

259059, F

35

350-415 V (3)

23,000

15,300

30 (13.5)

0.0272 (0.1034)

2000 (14, 140)

Part, Series

Full Load Peak 
Amps*

Nominal Voltage 
Range (phase)

System 
Watts†

Primary 
Heater 
Watts

Max Flow 
Rate

gpm (lpm)

Approximate 
Output per Cycle 
(A+B)
gal. (liter)

Maximum Fluid 
Working Pressure 
psi (MPa, bar)

259024, G

69

200-240 V (1)

15,800

10,200

1.0 (3.8)

0.0104 (0.0395)

2500 (17.2, 172)

259029, G

24

350-415 V (3)

15,800

10,200

1.0 (3.8)

0.0104 (0.0395)

2500 (17.2, 172)

259033, G

43

200-240 V (3)

15,800

10,200

1.0 (3.8)

0.0104 (0.0395)

2500 (17.2, 172)

Part, Series

Full Load Peak 
Amps* 

Nominal Voltage 
Range (phase)

System 
Watts†

Primary 
Heater 
Watts

Max Flow 
Rate

gpm (lpm)

Approximate 
Output per Cycle 
(A+B)
gal. (liter)

Maximum Fluid 
Working Pressure 
psi (MPa, bar)

259028, F

100

200-240 V (1)

23,000

15,300

2.0 (7.6)

0.0203 (0.0771)

3500 (24.1, 241)

259032, F

35

350-415 V (3)

23,000

15,300

2.0 (7.6)

0.0203 (0.0771)

3500 (24.1, 241)

259036, F

62

200-240 V (3)

23,000

15,300

2.0 (7.6)

0.0203 (0.0771)

3500 (24.1, 241)

Summary of Contents for REACTOR E-XP1

Page 1: ...tmosphere locations See page 3 for model information including maximum working pressure and approvals Important Safety Instructions Read all warnings and instructions in this manual and in manuals 312065 and 312066 Save all instruction manuals WL E Model E XP1 Shown Electrical Diagrams 312067H EN 9902471 Conforms to ANSI UL Std 499 Certified to CAN CSA Std C22 2 No 88 ...

Page 2: ...d Warranty 12 Graco Information 12 Supplied Manuals The following manuals are shipped with the Reactor Proportioner Refer to these manuals for detailed equip ment information Manuals are also available at www graco com Reactor Electric Proportioner Operation Part Description 312065 Reactor Electric Proportioner Operation Manual English Reactor Electric Proportioner Repair Parts Part Description 31...

Page 3: ...er Maximum Fluid Working Pressure psi MPa bar 259026 F 78 200 240 V 1 17 900 10 200 30 13 5 0 0272 0 1034 2000 14 140 259031 F 34 350 415 V 3 17 900 10 200 30 13 5 0 0272 0 1034 2000 14 140 259035 F 50 200 240 V 3 17 900 10 200 30 13 5 0 0272 0 1034 2000 14 140 259057 F 100 200 240 V 1 23 000 15 300 30 13 5 0 0272 0 1034 2000 14 140 259058 F 62 200 240 V 3 23 000 15 300 30 13 5 0 0272 0 1034 2000 ...

Page 4: ...Simplified Schematics Motor Controls 4 312067H Simplified Schematics Motor Controls E 20 and E XP1 Series ...

Page 5: ...Simplified Schematics Motor Controls 312067H 5 Simplified Schematics Motor Controls cont E 30 and E XP2 Series ...

Page 6: ...Simplified Schematic Heater Controls 6 312067H Simplified Schematic Heater Controls ...

Page 7: ...Simplified Schematic Power Connections 312067H 7 Simplified Schematic Power Connections 200 240 V ac 1 phase 200 240 V ac 3 phase 350 415 V ac 3 phase ...

Page 8: ...Detailed Schematic Motor Controls 8 312067H Detailed Schematic Motor Controls B A 24G879 E 20 and E XP1 Series ...

Page 9: ...Detailed Schematic Motor Controls 312067H 9 Detailed Schematic Motor Controls cont 24G881 E 30 and E XP2 Series ...

Page 10: ...Detailed Schematic Heater Controls 10 312067H Detailed Schematic Heater Controls ...

Page 11: ...Detailed Schematic Heater Controls 312067H 11 ...

Page 12: ...n material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warr...