ProMix™ II General Operating Cycle
◆
Air Flow Switch Function
310633C
11
Air Flow Switch Function
Air or Air-assisted Airless Guns
The air flow switch detects air flow to the gun and sig-
nals the ProMix™ II controller when the gun is being
triggered. The switch functions with the flow meters to
ensure that the system components are functioning cor-
rectly.
For example, if a flow meter fails or clogs, pure resin or
catalyst could spray indefinitely if the ProMix™ II does
not detect the condition and intervene, which is why the
air flow switch is so important.
If the ProMix™ II controller detects through the air flow
switch signal that the gun is triggered, yet there is no
fluid flow through the meter, a Dose Time Alarm (page
54) occurs after 40 seconds and the system shuts down.
Operating Without Air Flow Switch
It is possible to operate the ProMix™ II without the air
flow switch, such as when a switch fails or when using
an airless gun.
Airless Gun
If using an airless gun or operating without the air flow
switch (not recommended), the dose time alarm will not
function. Instead, two minutes after a meter fails, the
system generates an Idle Time Warning and the dis-
pense valves turn off. What this means is:
•
It is possible to spray pure resin or catalyst for up to
2 minutes before the system shuts down.
•
Since the Idle Time Warning can occur during nor-
mal operation, you may not immediately realize that
a meter failed and may continue painting.
Idle Time Warning
This warning occurs if the ProMix™ II is set to Mix
,
and 2 minutes have elapsed since the system received
a flow meter pulse.
In applications using the air flow switch, triggering the
gun clears the warning and the operator can start spray-
ing again.
Without the air flow switch, triggering the gun does not
clear the alarm. To start spraying again, you must press
Mix
, then trigger the gun.
F
IG
. 2
Fluid Manifold Cutaway
H
D
C
A
F
E
G
J
K
L
M
Key:
A
Dispense Valve A
B
Dispense Valve B
C Flow Meter A
D Component A Supply Line
E
Air Purge Valve
F
Shutoff Valve A
G Flow Meter B
H Component B Supply Line
J
Solvent Purge Valve
K
Integrator
L
Static Mixer
M Fluid Supply to Gun
B
If a switch fails, replace it as soon as possible.