![Graco ProMix Easy Series Manual Download Page 20](http://html.mh-extra.com/html/graco/promix-easy-series/promix-easy-series_manual_2251702020.webp)
Priming
20
309908G
Priming
Do not install the gun spray tip yet. Use the lowest
possible pressure while priming, to avoid splash-
ing.
1.
Connect A and B fluid supply hoses to A and B
pumps/meters.
2.
Pump-based models only: Set air regulator to 0.
3.
Close fluid shutoff valves G
A
and G
B
.
G
A
G
B
4.
Place a container under each sampling valve. Open
sampling valve H
A
slowly.
5.
Turn function knob to A
. Press
. On
pump-based models only, turn up air regulator
slowly until pump A starts.
H
A
When run independently (set to A or B), the pump
runs for 12 cycles, then stops. Press
and
as needed to prime. Monitor containers to avoid
overflowing.
Summary of Contents for ProMix Easy Series