Performance Charts
18
3A1450B
Performance Charts
Fluid Outlet Pressure
To find fluid outlet pressure (MPa/bar/psi) at a specific flow
(lpm/gpm) and operating pressure (A/B/C):
1.
Locate desired flow at bottom of chart.
2.
Follow vertical line up to intersection with selected operat-
ing pressure curve (solid line). Follow left to scale to read
fluid outlet pressure.
Air Consumption
To find air consumption (l/min. or gpm) at a specific fluid flow
(l/min. or gpm) and operating pressure (A/B/C):
1.
Locate desired flow along bottom of chart.
2.
Read vertical line up to intersection with selected air con-
sumption curve (dashed line). Follow left to scale to read
air consumption.
Key
A
0.7 MPa, 7 bar (100 psi) air pressure
B
0.5 MPa, 4.9 bar (70 psi) air pressure
C
0.3 MPa, 2.8 bar (40 psi) air pressure
Test Fluid: No. 10 Weight Oil
3:1 President with 750cc Lower
500
(3.5, 35)
A
B
A
B
C
Fl
ui
d Pre
ssu
re
psi (MPa, bar)
300
(2.0, 20)
200
(1.3, 13)
100
(0.69, 6.9)
Air Cons
umption
40
(1.12)
C
0
30
(0.84)
20
(0.56)
10
(0.28)
scfm (m
3
/min)
50
(1.40)
2.0
(7.5)
6.0
(22.7)
10.0
(37.8)
14.0
(53.0)
4.0
(15.1)
8.0
(30.2)
12.0
(45.4)
Fluid Flow in gpm (lpm)
0
2.0
(7.5)
6.0
(22.7)
10.0
(37.8)
14.0
(53.0)
4.0
(15.1)
8.0
(30.2)
12.0
(45.4)
Fluid Flow in gpm (lpm)
400
(2.7, 27)
2:1 President with 1000cc Lower
400
(2.7, 27)
2.0
(7.5)
6.0
(22.7)
10.0
(37.8)
14.0
(53.0)
4.0
(15.1)
8.0
(30.2)
12.0
(45.4)
A
B
A
B
C
F
lui
d Pres
su
re
psi (MPa, bar)
300
(2.0, 20)
200
(1.3, 13)
100
(0.69, 6.9)
0
Fluid Flow in gpm (lpm)
Air Consumption
40
(1.12)
C
0
30
(0.84)
20
(0.56)
10
(0.28)
16.0
(60.8)
50
(1.40)
2.0
(7.5)
6.0
(22.7)
10.0
(37.8)
14.0
(53.0)
4.0
(15.1)
8.0
(30.2)
12.0
(45.4)
Fluid Flow in gpm (lpm)
16.0
(60.8)
scfm (m
3
/min)
12
25
37
49
61
73
86
cycles per minute
12
25
37
49
61
73
86
cycles per minute
9
18
28
37
46
55
64
cycles per minute
74
9
18
28
37
46
55
64
cycles per minute
74
Summary of Contents for President 24H627
Page 14: ...Repair 14 3A1450B...