Troubleshooting
28
3A2152B
Machine Alarms
The following is a list of possible alarms.
#
DESCRIPTION
TYPE
CAUSE
SOLUTION
1
INPUT POWER OFF FAULT
Alarm
N/A
N/A
2
CONTROL POWER OFF FAULT
Alarm
Power on button not
pressed/Estop pressed
Push power on button
3
24VDC POWER OFF FAULT
Alarm
N/A
N/A
4
BASE PUMP OVERTRAVEL
Shutdown
Pump is extended too
far in either direction
Get pump back within travel
limits
5
INHIBITOR PUMP OVERTRAVEL
Shutdown
6
CATALYST PUMP OVERTRAVEL
Shutdown
7
COLOR PUMP OVERTRAVEL
Shutdown
8
BASE PUMP OVER CURRENT
Shutdown
Motor or transmission
malfunction
Check/replace motor or
transmission
9
INHIBITOR PUMP OVER CURRENT
Shutdown
10 CATALYST PUMP OVER CURRENT
Shutdown
11 COLOR PUMP OVER CURRENT
Shutdown
12 BASE DRIVE OVER TEMP
Shutdown
Excessive heat exists in
the power circuitry
Reduce duty cycle, check
for clogged vents, defective
fan
13 INHIBITOR DRIVE OVER TEMP
Shutdown
14 CATALYST DRIVE OVER TEMP
Shutdown
15 COLOR DRIVE OVER TEMP
Shutdown
16 BASE MOTOR OVER TEMP
Shutdown
High ambient motor
temperature and/or
excessive current
Operate within continuous
torque rating for ambient
temperature maximum
17 INHIBITOR MOTOR OVER TEMP
Shutdown
18 CATALYST MOTOR OVER TEMP
Shutdown
19 COLOR MOTOR OVER TEMP
Shutdown
20 BASE DRIVE FEEDBACK ERROR
Shutdown
Feedback wiring is
open, shorted, or miss-
ing
Check motor encoder wiring.
21 INHIBITOR DRIVE FEEDBACK ERROR
Shutdown
22 CATALYST DRIVE FEEDBACK ERROR
Shutdown
23 COLOR DRIVE FEEDBACK ERROR
Shutdown
24 BASE DRIVE OVERLOAD
Shutdown
Load limit of motor/drive
has been exceeded
Check for blocked fluid path
25 INHIBITOR DRIVE OVERLOAD
Shutdown
26 CATALYST DRIVE OVERLOAD
Shutdown
27 COLOR DRIVE OVERLOAD
Shutdown
28 BASE MOTOR POSITION ERROR
Shutdown
Position error limit was
exceeded
Check for blocked fluid path
29 INHIBITOR MOTOR POSITION ERROR
Shutdown
30 CATALYST MOTOR POSITION ERROR
Shutdown
31 COLOR MOTOR POSITION ERROR
Shutdown
32 BASE RATIO CHECK SHOT OUT OF RANGE
Alarm
Shot size entered too
large or small
Change shot size within lim-
its
33 INHIBITOR RATIO CHECK SHOT OUT OF RANGE Alarm
34 CATALYST RATIO CHECK SHOT OUT OF RANGE Alarm
35 COLOR RATIO CHECK SHOT OUT OF RANGE
Alarm
36 BASE AXIS FAULT
Shutdown
Drive has faulted
Check drive diagnostic win-
dow
37 INHIBITOR AXIS FAULT
Shutdown
38 CATALYST AXIS FAULT
Shutdown
39 COLOR AXIS FAULT
Shutdown
Summary of Contents for LSR Select
Page 7: ...Important Two Component Material Information 3A2152B 7...
Page 50: ...Parts 50 3A2152B Base Pump Wet Section 24L880 ti18115a 201 202...
Page 60: ...Parts 60 3A2152B Valve Stack 24L893 ti18160a 704 706 708 703 702 701 705 707 709 712 711 710...
Page 83: ...Control Schematics 24L890 3A2152B 83...
Page 93: ...Appendix A HMI Screens Overview 3A2152B 93...
Page 111: ...Accessories 3A2152B 111...