Operation
18
3A2152B
Pressure Relief Procedure
Pressure Relief Method with Power:
1. If the mixer is connected to the screw of the press,
put a container at the end of the screw.
2. Use the press controls to bleed the screw of mate-
rial.
3. Go to the DRIVE/VALVE CONTROL screen.
4. Press the SET MAN'L MODE button.
5. Press the OPEN SCREW VALVE button.
6. Let the pressure drop to 0 psi/MPa/bar.
Pressure Relief Method with No Power:
1. If the mixer is connected to the screw of the press,
put a container at the end of the screw.
2. Use the press controls to bleed the screw of mate-
rial.
3. Press the orange override buttons on the solenoid
valve assembly.
4. Let the pressure drop to 0 psi/Mpa/bar.
In the following step, any pressure in the lines will be
instantly relieved which may lead to material spraying
out of the valve and splashing in the bucket. Use
appropriate protective wear to prevent contact with
materials.
NOTICE
This procedure relieves pressure from the dispense
lines only. To avoid personal injury, refer to the feed
system documentation to relieve pressure from the
feed lines.
F
IG
. 14: Override Button
ti18105a
Summary of Contents for LSR Select
Page 7: ...Important Two Component Material Information 3A2152B 7...
Page 50: ...Parts 50 3A2152B Base Pump Wet Section 24L880 ti18115a 201 202...
Page 60: ...Parts 60 3A2152B Valve Stack 24L893 ti18160a 704 706 708 703 702 701 705 707 709 712 711 710...
Page 83: ...Control Schematics 24L890 3A2152B 83...
Page 93: ...Appendix A HMI Screens Overview 3A2152B 93...