Setup
3A9099A Operation, Repair, Parts
15
Setup
The ProConnect
®
(PC) Fluid Cartridge (20) comes
pre-installed along with two spares for future use. See
Reinstall or Replace the PC Fluid Cartridge
to learn when to replace the fluid cartridge.
Assemble the Spray Gun
1. Install the Mix Chamber (13).
a. Lubricate the Fluid Housing (6) and Mix
Chamber (13) sealing surfaces and ramp. See
b. Match A and B sides of the Mix Chamber (13)
to corresponding sides of the Fluid Housing (6).
Insert keyed end of the Mix Chamber into the
socket on the Handle (8).
NOTE:
The slot on the mix chamber should be facing
downward.
2. Engage the Piston Safety Lock (11). See
3. Install the PC Fluid Cartridge (20).
a. Align the cartridge so it slides over the Mix
Chamber (13) until the side seals engage the
ramp.
b. Press the PC Fluid Cartridge (20) onto the Mix
Chamber (13). The fluid ports on the cartridge
will engage the Fluid Housing (6). Resistance
will be felt as the side seals are depressed.
c. Fully engage the PC Fluid Cartridge (20) into
the Fluid Housing (6) until the back face of the
cartridge is flush with the Fluid Housing.
WLE
13
13
6
8
TI2409A
11
WLE
13
6
20