For the application of line striping materials.
For professional use only. 
For outdoor use only. 
Not for use in explosive atmospheres or hazardous locations.

Maximum Operating Pressure: 3300 psi (22.8 MPa, 228 bar)

Important Safety Instructions

Read all warnings and instructions in this manual and in related manuals. 
Be familiar with the controls and the proper usage of the equipment. 
Save these instructions.

LineLazer 130

HS

Model:

Standard 

1 Manual Gun

Standard

2 Manual Guns

17H447

17H448

Related Manuals:

3A3391

Parts

311254

Gun

311845

Pump

Operation

LineLazer

 130

HS

 Airless Line Stripers 

3A3392B

EN

Use only genuine Graco replacement parts.

The use of non-Graco replacement parts may void warranty.

ti28037a

Summary of Contents for LineLazer 130HS

Page 1: ...nings and instructions in this manual and in related manuals Be familiar with the controls and the proper usage of the equipment Save these instructions LineLazer 130HS Model Standard 1 Manual Gun Standard 2 Manual Guns 17H447 17H448 Related Manuals 3A3391 Parts 311254 Gun 311845 Pump Operation LineLazer 130HS Airless Line Stripers 3A3392B EN Use only genuine Graco replacement parts The use of non...

Page 2: ...1 Gun Placement 12 Install Guns 12 Position Gun 12 Select Guns 12 Gun Positions Chart 13 Gun Arm Mounts 14 Change Gun Position Front and Back 14 Change Gun Position Left and Right 15 Installation 15 Gun Cable Adjustment 15 Straight Line Adjustment 16 Handle Bar Adjustment 16 Cleanup 17 Maintenance 18 LineLazer 130HS 18 Troubleshooting 19 Hydraulic Oil Filter Change 21 Removal 21 Installation 21 Te...

Page 3: ...iners unless they are anti static or conductive Stop operation immediately if static sparking occurs or you feel a shock Do not use equipment until you identify and correct the problem Keep a working fire extinguisher in the work area SKIN INJECTION HAZARD High pressure spray is able to inject toxins into the body and cause serious bodily injury In the event that injection occurs get immediate sur...

Page 4: ...distributor for information Route hoses and cables away from traffic areas sharp edges moving parts and hot surfaces Do not kink or over bend hoses or use hoses to pull equipment Keep children and animals away from work area Comply with all applicable safety regulations PRESSURIZED ALUMINUM PARTS HAZARD Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious ch...

Page 5: ...RSONAL PROTECTIVE EQUIPMENT Wear appropriate protective equipment when in the work area to help prevent serious injury including eye injury hearing loss inhalation of toxic fumes and burns This protective equipment includes but is not limited to Protective eyewear and hearing protection Respirators protective clothing and gloves as recommended by the fluid and solvent manufacturer CALIFORNIA PROPO...

Page 6: ...0 LL5325 4 10 LL5327 4 10 LL5329 4 10 LL5331 4 10 LL5333 4 10 LL5335 4 10 LL5355 4 10 LL5417 6 15 LL5419 6 15 LL5421 6 15 LL5423 6 15 LL5425 6 15 LL5427 6 15 LL5429 6 15 LL5431 6 15 LL5435 6 15 LL5621 12 30 LL5623 12 30 LL5625 12 30 LL5627 12 30 LL5629 12 30 LL5631 12 30 LL5635 12 30 LL5639 12 30 ti27606a in cm ti27505a in cm ti27506a in cm ti27507a in cm ti27508a ti27509a ti27510a ti27605a ...

Page 7: ...ification LL 130HS 8 1 3 6 2 7 9 10 1 3 2 5 4 6 7 8 10 9 4 5 ti28038a 1 Manual spray gun trigger 2 Storage box 3 Filter 4 Pressure gauge 5 Prime Pressure relief valve 6 Pump ON OFF lever 7 Drain and siphon tubes 8 Pressure control 9 Engine ON OFF switch 10 Trigger safety ...

Page 8: ...down 5 If you suspect the spray tip or hose is clogged or that pressure has not been fully relieved a VERY SLOWLY loosen the tip guard retaining nut or the hose end coupling to relieve pressure gradually b Loosen the nut or coupling completely c Clear the obstruction in the hose or tip This equipment must be grounded to reduce the risk of static sparking Static sparking can cause fumes to ignite o...

Page 9: ...west pressure NOTE Minimum hose size allowable for proper sprayer operation is 3 8 in x 22 ft for LL130HS 9 Place siphon tube set in grounded metal pail par tially filled with flushing fluid Attach ground wire to true earth ground Use water to flush water base paint and mineral spirits to flush oil base paint and storage oil This equipment stays pressurized until pressure is manually relieved To h...

Page 10: ... Move fuel valve to open b Move choke to closed c Set throttle to fast d Set engine switch to ON e Pull starter cord 11 After engine starts move choke to open 12 Set throttle to desired setting ti27616a ti27617a ti5250a ti27619a ti27620a ti27766a ti5250a ...

Page 11: ...e Tighten leaky fittings Repeat Setup Startup steps 1 17 If no leaks continue to trigger gun until system is thoroughly flushed Proceed to step 18 18 Place siphon tube in paint pails 19 Trigger all guns again into a flushing fluid pail until paint appears Assemble tips and guards SwitchTip and Guard Assembly 1 Engage trigger lock Use end of SwitchTip to press OneSeal into tip guard with curve matc...

Page 12: ...can be rotated for clearance Another option can be to swing the gun out at an angle and rotate the tip guard This results in better visibility for the user Select Guns 3 Connect gun cables to left or right gun selector plates a One gun Disconnect one gun selector plate from trigger b Both guns simultaneously Adjust both gun selector plates to the same position c Solid skip and skip solid Adjust so...

Page 13: ...on 13 Gun Positions Chart 1 One line 2 One line up to 24 in 61cm wide 3 Two lines 4 One line or two lines to spray around obstacles 5 One gun curb 6 Two gun curb 7 Two lines or one line up to 24 in 61 cm wide 1 2 3 4 5 6 7 ti27786a ...

Page 14: ... 2 Slide gun arm assembly including gun and hoses out from gun arm mounting slot 3 Slide gun arm assembly into desired gun arm mounting slot 4 Tighten gun arm knob into gun arm mounting slot ti28042a ti27796a NOTICE Make sure all hoses cables and wires are properly routed through brackets and do NOT rub on tire Contact with tire will result in damaged hoses cables and wires ti27795a ti27797a ti277...

Page 15: ...are properly routed through brackets Gun Cable Adjustment Adjusting the gun cable will increase or decrease the gap between the trigger plate and the gun trigger To adjust trigger gap perform the steps below 1 Use wrench to loosen locking nut on cable adjuster 2 Loosen or tighten adjuster until desired result is achieved NOTE More thread exposed means less gap between gun trigger and trigger plate...

Page 16: ...form the following steps 1 Loosen bolt on the front wheel bracket 2 If striper arcs to the right loosen left set screw and tighten right set screw for fine tune adjustment 3 If striper arcs to the left loosen right set screw and tighten left set screw 4 Roll the striper Repeat steps 2 and 3 until striper rolls straight Tighten bolt on wheel alignment plate to lock the new wheel setting Handle Bar ...

Page 17: ... flush oil base paint 6 Hold gun against paint bucket and pull trigger until water or solvent appears 7 Move gun to solvent or water bucket Hold gun against bucket and pull trigger until the system is thoroughly flushed 8 Fill pump with Pump Armor and reassemble filter guard and SwitchTip 9 Each time you spray and store fill throat packing nut with TSL to decrease packing wear This equipment stays...

Page 18: ...ating in an unusually dusty environment check filter daily WEEKLY DAILY Remove any debris from hydraulic rod AFTER EACH 100 HOURS OF OPERATION Change engine oil Reference Honda Engines Owner s Manual for correct oil viscosity SEMI ANNUALLY Check belt wear replace if neces sary YEARLY OR 2000 HOURS Replace hydraulic oil and filter element with Graco hydraulic oil 169236 5 gal lon 18 9 liter or 2074...

Page 19: ... to dried paint Repair pump Manual 311845 Belt worn broken or off pulley Replace Hydraulic fluid too low Shut of sprayer Add fluid Hydraulic motor not shifting Set pump valve OFF Turn pressure down Turn engine OFF Pry rod up or down until hydraulic motor shifts Displacement pump operates but output is low on upstroke Piston ball is not seating Service piston ball Manual 311845 Piston packings are ...

Page 20: ...acking nut spacer Tighten throat packing nut just enough to stop leakage Throat packings are worn or damaged Replace packings Manual 311845 Displacement rod is worn or damaged Replace rod Manual 311845 Fluid is spitting from gun Air in pump or hose Check and tighten all fluid connections Reprime pump Tip is partially clogged Clear tip Manual 311254 Fluid supply is low or empty Refill fluid supply ...

Page 21: ...ght film of oil on filter gasket Install drain plug and oil filter Tighten oil filter 3 4 turn after gas ket contacts base 2 Fill with five quarts of Graco hydraulic oil 169236 5 gallon 20 liter or 207428 1 gallon 3 8 liter 3 Check oil level This equipment stays pressurized until pressure is manually relieved To help prevent serious injury from pressurized fluid such as skin injection splash ing f...

Page 22: ...essure 1825 psi 124 bar Maximum Tip Size 1 gun 0 037 in 2 guns 0 029 in Noise level dBa Sound power 110 dBa per ISO 3744 Sound pressure 96 dBa measured at 3 1 feet 1m Vibration level Left Hand 2 90 m sec2 Right Hand 2 83 m sec2 Vibration measured per ISO 5349 bsed on 8 hr daily exposure Inlet Outlet Sizes Inlet paint strainer 16 mesh 1190 micron stainless steel screen reusable Outlet paint filter ...

Page 23: ...Notes 3A3392B Operation 23 Notes ...

Page 24: ... distributor for verification of the claimed defect If the claimed defect is verified Graco will repair or replace free of charge any defective parts The equipment will be returned to the original purchaser transportation prepaid If inspection of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of ...