Repair
24
334627K
5.
Hold a rag over the manifold air ports and turn the
air supply ON to clean the ports as shown in
Figure
19
.
6.
Cycle the solenoid by pushing the blue button on the
solenoid.
7.
Turn off the air supply and remove the rag.
8.
Apply the high-temperature lubricant to the air
section o-rings (2b) and the fluid section o-ring (2a)
in the module (2).
NOTE:
The air section o-rings are brown and the fluid
section o-ring is black. All o-rings are fluoroelastomer.
The color is only used to identify the difference in size.
9.
Apply anti-seize to the two screw threads (22). Use
a 3 mm Allen wrench to install the new module (2)
on the manifold with the two screws (22). Torque to
28-32 in-lb (3.2-3.6 N•m).
10. Connect the cordset (17) to the heated hose.
Replace Applicator
1.
Disable the applicator. See
Before Beginning
Repair
on page
.
2.
Loosen the mounting bar clamp and remove the
applicator from the mounting bar.
3.
Install the new applicator. See
Installation
on page
F
IG
. 19
WLD
Summary of Contents for InvisiPac GM100 Plug-Free
Page 25: ...Repair 334627K 25 Notes ...