background image

Operation

Husky™

Husky™

Husky™ 3300e

3300e

3300e

Electric

Electric

Electric---Operated

Operated

Operated Diaphragm

Diaphragm

Diaphragm Pump

Pump

Pump

3A7036E

3A7036E

3A7036E

EN

EN

EN

3

3

3---Inch

Inch

Inch pumps

pumps

pumps with

with

with electric

electric

electric drive

drive

drive for

for

for fluid

fluid

fluid transfer

transfer

transfer applications.

applications.

applications. Not

Not

Not approved

approved

approved for

for

for use

use

use in

in

in explosive

explosive

explosive

atmospheres

atmospheres

atmospheres or

or

or hazardous

hazardous

hazardous (classified)

(classified)

(classified) locations

locations

locations unless

unless

unless otherwise

otherwise

otherwise stated.

stated.

stated. For

For

For professional

professional

professional use

use

use only.

only.

only.

Important

Important

Important Safety

Safety

Safety Instructions

Instructions

Instructions

Read all warnings and instructions in this manual and in your
Repair/Parts manual. Save

Save

Save all

all

all instructions.

instructions.

instructions.

Maximum Working Pressure: 80 psi

(0.55 MPa, 5.5 bar)

PROVEN QUALITY. LEADING TECHNOLOGY.

All manuals and user guides at all-guides.com

Summary of Contents for Husky 3300e

Page 1: ...explosive atmospheres atmospheres atmospheres or or or hazardous hazardous hazardous classified classified classified locations locations locations unless unless unless otherwise otherwise otherwise s...

Page 2: ...Adjust the the the Pump Pump Pump 18 18 18 Pressure Pressure Pressure Relief Relief Relief Procedure Procedure Procedure 19 19 19 Pump Pump Pump Shutdown Shutdown Shutdown 19 19 19 VFD VFD VFD Operat...

Page 3: ...ARD HAZARD Flammable fumes such as solvent and paint fumes in work work work area area area can ignite or explode Paint or solvent flowing through the equipment can cause static sparking To help preve...

Page 4: ...nd follow the Pressure Pressure Pressure Relief Relief Relief Procedure Procedure Procedure when equipment is not in use Check equipment daily Repair or replace worn or damaged parts immediately with...

Page 5: ...Safety Data Sheet SDS and recommendations TOXIC TOXIC TOXIC FLUID FLUID FLUID OR OR OR FUMES FUMES FUMES HAZARD HAZARD HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the...

Page 6: ...old Manifold Manifold O O O Rings Rings Rings NOTE NOTE NOTE Some Some Some combinations combinations combinations are are are not not not possible possible possible Please Please Please refer refer r...

Page 7: ...elastomer S51 S51 S51 Stainless Stainless Stainless steel steel steel center center center flange flange flange PP PP PP Polypropy Polypropy Polypropy lene lene lene GE GE GE Geolast Geolast Geolast S...

Page 8: ...ation of of of a a a New New New Pump Pump Pump Please Please Please call call call your your your distributor distributor distributor OR OR OR Use the Online Online Online Electric Electric Electric...

Page 9: ...formation and and and collapse collapse collapse of of of bubbles bubbles bubbles in in in the the the pumped pumped pumped liquid liquid liquid Frequent Frequent Frequent or or or excessive excessiv...

Page 10: ...e master air valve when closed relieves air pressure between valve and pump E Air inlet port H Air filter regulator assembly remove dirt and moisture in air supply limit air pressure to pump P Pump Gr...

Page 11: ...let port A Power cord to VFD C Fluid outlet port F Power cord to compressor D Mounting feet K Grounded flexible fluid supply line E Air inlet port L Fluid drain valve allow release of any pressurized...

Page 12: ...ble wobble wobble 3 3 3 Bolt Bolt Bolt the the the pump pump pump to to to the the the floor floor floor through through through the the the mounting mounting mounting holes holes holes B B B to to to...

Page 13: ...tor Motors have a ground screw in the electrical box Use it to ground the motor to the controller Air Air Air Line Line Line and and and Fluid Fluid Fluid hoses hoses hoses Use only grounded hoses wit...

Page 14: ...s is is 2 2 2 in in in npt f npt f npt f or or or 2 2 2 in in in bspt bspt bspt On On On pumps pumps pumps with with with polypropylene polypropylene polypropylene conductive conductive conductive pol...

Page 15: ...to to to T2 T2 T2 and and and L3 L3 L3 to to to T3 T3 T3 T4 T5 T6 L2 L3 L1 T7 T8 T9 T1 T2 T3 Figure Figure Figure 3 3 3 Wire Wire Wire Connections Connections Connections for for for a a a 230 230 230...

Page 16: ...ly closed normally closed circuit circuit circuit 1 1 1 Turn Turn Turn off off off power power power to to to the the the VFD VFD VFD 2 2 2 Open Open Open the the the access access access cover cover...

Page 17: ...er connections connections connections i e i e i e conduit fittings conduit fittings conduit fittings power power power cable cable cable cable cable cable grip grip grip to to to the the the compress...

Page 18: ...Tighten Tighten fluid fluid fluid inlet inlet inlet and and and fluid fluid fluid outlet outlet outlet fittings fittings fittings securely securely securely 3 3 3 Place Place Place the the the suctio...

Page 19: ...ner container container ready ready ready to to to catch catch catch the the the drainage drainage drainage 3 3 3 Remove Remove Remove supply supply supply air air air to to to the the the pump pump p...

Page 20: ...r motor motor The The The blue blue blue M M M key key key accesses accesses accesses the the the VFD VFD VFD menu menu menu See See See the the the manufacturer s manufacturer s manufacturer s instru...

Page 21: ...all all hoses hoses hoses for for for wear wear wear or or or damage damage damage and and and replace replace replace as as as necessary necessary necessary Check Check Check to to to be be be sure s...

Page 22: ...quing manifolds 1 1 1 Start Start Start all all all fluid fluid fluid cover cover cover screws screws screws a a a few few few turns turns turns Then Then Then turn turn turn down down down each each...

Page 23: ...e bolts 5 12 to 40 45 ft lb 54 60 N m SIDE VIEW TOP BOTTOM VIEW Polypropylene Polypropylene Polypropylene Conductive Conductive Conductive Polypropylene Polypropylene Polypropylene PVDF PVDF PVDF Pump...

Page 24: ...lower lower lower than than than 10 10 10 psi psi psi 0 7 0 7 0 7 bar bar bar and and and with with with high high high inlet inlet inlet head head head pressure pressure pressure 4 4 4 To To To prev...

Page 25: ...uation NPSHa NPSHa NPSHa H H Ha a a H H Hz z z H H Hf f f H H Hv v vp p p Where Where Where H H Ha a a is the absolute pressure on the surface of the liquid in the supply tank Typically this is atmosp...

Page 26: ...Dimensions Dimensions Dimensions Dimensions Aluminum pump with compressor 26 3A7036E All manuals and user guides at all guides com...

Page 27: ...Dimensions Aluminum pump without compressor 3A7036E 27 All manuals and user guides at all guides com...

Page 28: ...23 6 59 9 D D D 17 4 44 2 17 4 44 2 18 4 46 7 10 7 27 2 E E E 2 0 5 1 2 0 5 1 2 0 5 1 2 0 5 1 2 0 5 1 F F F 17 5 44 5 17 5 44 5 17 5 44 5 17 5 44 5 17 5 44 5 G G G 34 6 87 9 34 6 87 9 41 4 105 2 43 8...

Page 29: ...Dimensions Polypropylene pump with compressor 3A7036E 29 All manuals and user guides at all guides com...

Page 30: ...Dimensions Polypropylene pump without compressor 30 3A7036E All manuals and user guides at all guides com...

Page 31: ...7 65 3 25 7 65 3 D D D 18 2 46 2 18 2 46 2 19 2 48 8 11 5 29 2 E E E 3 5 8 9 3 5 8 9 3 5 8 9 3 5 8 9 3 5 8 9 F F F 19 7 50 0 19 7 50 0 19 7 50 0 19 7 50 0 19 7 50 0 G G G 34 6 87 9 34 6 87 9 41 4 105...

Page 32: ...Dimensions Stainless steel pump with compressor 32 3A7036E All manuals and user guides at all guides com...

Page 33: ...Dimensions Stainless steel pump without compressor 3A7036E 33 All manuals and user guides at all guides com...

Page 34: ...26 3 66 8 26 3 66 8 D D D 19 6 50 0 19 6 50 0 20 7 52 6 13 0 33 0 E E E 2 5 6 4 2 5 6 4 2 5 6 4 2 5 6 4 2 5 6 4 F F F 18 1 46 0 18 1 46 0 18 1 46 0 18 1 46 0 18 1 46 0 G G G 34 6 87 9 34 6 87 9 41 4...

Page 35: ...ns gallons gallons 4 45 4 45 4 45 liters liters liters Maximum Maximum Maximum free free free flow flow flow delivery delivery delivery 90 90 90 Hz Hz Hz 220 220 220 gpm gpm gpm 830 830 830 lpm lpm lp...

Page 36: ...dBa at at at 60 60 60 psi psi psi fluid fluid fluid pressure pressure pressure and and and 160 160 160 cpm cpm cpm full full full flow flow flow 92 92 92 dBa dBa dBa Sound Sound Sound Pressure Pressur...

Page 37: ...ps Pumps PVDF PVDF PVDF Pumps Pumps Pumps Diaphragm Ball Seat Diaphragm Ball Seat Diaphragm Ball Seat Material Material Material Fahrenheit Fahrenheit Fahrenheit Celsius Celsius Celsius Fahrenheit Fah...

Page 38: ...TY WARRANTY WARRANTY AND AND AND DISCLAIMS DISCLAIMS DISCLAIMS ALL ALL ALL IMPLIED IMPLIED IMPLIED WARRANTIES WARRANTIES WARRANTIES OF OF OF MERCHANTABILITY MERCHANTABILITY MERCHANTABILITY AND AND AND...

Reviews: