Troubleshooting
3A7600C
33
DCS Actuator Rod Does Not Move
Use this flow chart if the DCS Actuator Rod does not
move or if the DCS displays error code E09 (Hall Sensor
Error). Reference
YES
NO
Turn power switch to OFF. Remove the blue shroud behind the DCS Control.
Ensure you have a good 12V battery installed. Disconnect the actuator motor
wires and signal cable from the DCS Control. Connect a multimeter between
the blue and brown wires on the DCS Control. Turn the power switch to ON.
Measure the voltage (DC) within 10 seconds of turning the power on. Does it
measure at least 3.0 VDC?
Connect the blue and brown wires on the
actuator to a good 12VDC battery. First try with
the blue wire on positive post and brown wire
on negative post. If the actuator rod does not
move, put the blue wire on the negative post
and the brown wire on the positive post. Does
the rod move in either case?
REPLACE
ACTUATOR
REPLACE
ACTUATOR
REPLACE DCS
CONTROL BOARD
REPLACE DCS
CONTROL BOARD
NO
NO
NO
YES
Within 10 seconds of turning the power switch to ON (while connected to
a good battery), measure the voltage (DC) between the red and black
wires on the actuator signal cable coming from the DCS Control. Does it
measure at least 10 VDC?
Reconnect the actuator motor wires and signal cable from the actuator to
the DCS Control. Turn the power switch to ON. Does the DCS Control
display the Run Screen within 5 seconds?
YES
YES
ti36057a
BLUE
BROWN
12V
Summary of Contents for GrindLazer 25P474
Page 50: ...Parts Dashboard Battery Assemblies Gas 50 3A7600C Parts Dashboard Battery Assemblies Gas...
Page 68: ...Wiring Diagram 68 3A7600C Wiring Diagram Gas Models...
Page 69: ...Wiring Diagram 3A7600C 69 Propane Models...
Page 70: ...Wiring Diagram 70 3A7600C Electric Models 480V...
Page 71: ...Wiring Diagram 3A7600C 71 Electric Models 380V...