Maintenance
16
311052E
7.
Turn off the solvent supply.
8.
Perform Pressure Relief Procedure, page 12.
9.
Disconnect the solvent supply hose from the gun.
10. Dip the end of a soft-bristle brush into a compatible
solvent. Do not continuously soak the brush's bris-
tles with solvent and do not use a wire brush.
11. With the gun pointed down, clean the front of the
gun, using the soft-bristle brush and solvent.
12. Scrub the air cap retaining ring (8), air cap (30), and
spray tip (9) with the soft-bristle brush. To clean out
air cap holes, use a soft tool, such as a toothpick, to
avoid damaging critical surfaces. Blow air through
the spray tip to ensure the orifice is clean. Clean the
air cap and spray tip daily, minimum. Some applica-
tions require more frequent cleaning.
13. Install the air cap retaining ring (8), air cap (30), and
spray tip (9).
14. Dampen a soft cloth with solvent and wring-out the
excess. Point the gun down and wipe off the outside
of the gun.
F
IG
. 14
TI4845A
F
IG
. 15
TI6570A