Technical Data
30
Installation and Operation
Technical Data
Fire-Ball 225 (3:1)
Fluid to air ratio......................................................... 3:1
Cycles/gallon (cycles/liter) ............................ 43.5 (11.4)
Fluid flow @80 cpm (gpm/lpm)....................... 1.84 (7.0)
Pumping distance guideline.......... up to 250 ft. (76.2 m)
Maximum fluid pressure ........ 540 psi (3.7 MPa, 37 bar)
Air motor effective diameter.............. 2.25 in. (57.2 mm)
Air operating range ............... 40-180 psi (0.28-1.2 MPa,
...................................................................... 2.8-12 bar)
Approx. air consumption and fluid flow @100 psi air and
80 cpm..... 8.5 scfm @2.1 gpm (.241 m
3
/min @7.9 lpm)
Dry suction lift (feet of water)......................................23
Wetted materials............steel, polyurethane, aluminum,
...............................................................buna-N, Rulon
®
Air inlet port size ......................................... 3/8 in. npt(f)
Fluid inlet port size ..................................... 1.5 in. npt(f)
Fluid outlet port size ................................... 1/2 in. npt(f)
Sound pressure (measured 1 meter from unit)... 77.8dB
Sound pressure (ISO 9614-2) ............................ 85.6dB
Fire-Ball 300 (5:1)
Fluid to air ratio......................................................... 5:1
Cycles/gallon (cycles/liter) .............................. 28.4 (8.6)
Fluid flow @80 cpm (gpm/lpm)......................... 2.8 (9.3)
Pumping distance guideline........ up to 500 ft. (152.5 m)
Maximum fluid pressure ........ 900 psi (6.2 MPa, 62 bar)
Air motor effective diameter................ 3.0 in. (76.2 mm)
Air operating range ............... 40-180 psi (0.28-1.2 MPa,
...................................................................... 2.8-12 bar)
Approx. air consumption and fluid flow @100 psi air and
80 cpm..... 8.5 scfm @2.1 gpm (.241 m
3
/min @7.9 lpm)
Dry suction lift (feet of water)......................................26
Wetted materials ........... steel, polyurethane, aluminum,
........................................................................... buna-N
Air inlet port size ......................................... 3/8 in. npt(f)
Fluid inlet port size ...................................... 1.5 in. npt(f)
Fluid outlet port size.................................... 1/2 in. npt(f)
Sound pressure (measured 1 meter from unit) ...77.8dB
Sound pressure (ISO 9614-2).............................85.6dB
Fire-Ball 425 (10:1)
Fluid to air ratio .......................................................10:1
Cycles/gallon (cycles/liter) ..............................19.6 (5.2)
Fluid flow @80 cpm (gpm/lpm) .......................4.1 (15.4)
Pumping distance guideline ........up to 750 ft. (228.6 m)
Maximum fluid pressure ...1800 psi (12.4 MPa, 124 bar)
Air motor effective diameter ............ 4.25 in. (107.9 mm)
Air operating range ...............40-180 psi (0.28-1.2 MPa,
......................................................................2.8-12 bar)
Approx. air consumption and fluid flow @100 psi air and
80 cpm .32.0 scfm @4.1 gpm (.555 m
3
/min @15.4 lpm)
Dry suction lift (feet of water) ..................................... 26
Wetted materials ..steel, polyurethane, aluminum, nitrile
Air inlet port size ......................................... 1/2 in. npt(f)
Fluid inlet port size ...................................... 1.5 in. npt(f)
Fluid outlet port size.................................... 3/4 in. npt(f)
Sound pressure (measured 1 meter from unit) .80.85dB
Sound pressure (ISO 9614-2)...........................94.62dB