Pressure Relief Procedure
10
334730F
Pressure Relief Procedure
Follow the Pressure Relief
Procedure whenever you see this
symbol.
1.
Set SELECTOR switch to
OFF
position.
Wait 7 seconds for power to dissipate.
2.
Engage trigger lock.
3.
Turn pressure control to lowest setting.
Disengage trigger lock.
4.
Hold a metal part of the gun firmly to a
grounded metal pail. Trigger the gun to
relieve pressure.
5.
Engage trigger lock.
This equipment stays pressurized until
pressure is manually relieved. To help
prevent serious injury from pressurized
fluid, such as skin injection, splashed fluid
and moving parts, follow the
Pressure
Relief Procedure
whenever sprayer is
stopped and before sprayer is cleaned or
checked, and before equipment is
serviced.
ti25541a
ti25450a
ti25446a