Automation Inputs
NOTE:
Print the following tables in color.
A Used for ambient map 18E218.
H Additional to ambient map for heated map 18E224.
Color Coded Key
Active Pump
Inactive Pump
Heat 1 for Pump 1
Heat 2 for Pump 2
E-Flo iQ Maps 18E218 and 18E224
Automation INPUTS (signal from E-Flo iQ to PLC)
Instanc
e ID
Description
Data
Type
Min
Value
Max
Value
Bit
Byte
Heat
1
Pump Heartbeat To PLC
Boolean
0
1
0
0
A
2
Automation Control Ready
Boolean
0
1
1
A
3
System Active
Boolean
0
1
2
A
4
Pump PLC Lockout/Control Active
Boolean
0
1
3
A
5
No Alarms are Present
Boolean
0
1
4
A
6
No Deviations are Present
Boolean
0
1
5
A
7
No Advisories are Present
Boolean
0
1
6
A
8
System Ready to dispense
Boolean
0
1
7
A
9
Pre-charge / De-charge Active
Boolean
0
1
0
1
A
10
Dispense In Process
Boolean
0
1
1
A
11
Drum Is Low
Boolean
0
1
2
A
12
Drum Is Empty
Boolean
0
1
3
A
13
Pump Not Primed
Boolean
0
1
4
A
14
Pump in Job Cycle
Boolean
0
1
5
A
15
Prime Active
Boolean
0
1
6
A
16
Valve Depressurization Active
Boolean
0
1
7
A
17
Platen Depressurization Active
Boolean
0
1
0
2
A
18
Auto Depressurization Active
Boolean
0
1
1
A
19
Auto Depressurization Happened
Boolean
0
1
2
A
20
Pump is trying to move
Boolean
0
1
3
A
21
Pump is actually moving
Boolean
0
1
4
A
22
Dispense Valve Opened
Boolean
0
1
5
A
23
Platen Valve Opened
Boolean
0
1
6
A
24
Tandem Active Pump (Tandem System only)
(0 = Pump 1, 1 = Pump 2)
Boolean
0
1
7
A