Technical Specifications
3A4100D
19
Technical Specifications
Not for use with group 1 fluids as defined by Directive 2014/68/EU (Pressure Equipment Directive).
Do not use fluids with a flash point exceeding the maximum operating temperature of the pump.
*
Tested at 18 cpm with an inlet air pressure of 0.45 MPa (4.5 bar, 65 psi) per ISO 9614-2.
+
Measured at a distance of 1 m (3.3 ft) from equipment at a height of 1.5m (4.9 ft).
California Proposition 65
Dura-Flo XL 1000cc Pumps
Models 25A451, 25A452, 25A453, 25A454
U.S.
Metric
Ratio
47:1
Maximum Fluid Working Pressure
4500 psi
31 MPa, 310 bar
Maximum Air Inlet Pressure
100 psi
0.7 MPa, 7 bar
Displacement Per Cycle
0.264 gallons
1000cc
Maximum Speed
30 cpm
Maximum Pump Operating Temperature
100° F
37.8° C
Stroke Length
11.25 in.
286 mm
Air Motor Piston Effective Area
132.7 in.
2
856 cm
2
Displacement Pump Effective Area
2.79 in.
2
18 cm
2
Total Sounds Power*
98 dBA
Average Sound Pressure *+
88.6 dBA
Air Inlet Size
1 in. npt(f)
Fluid Inlet Size
2 in. npt(f)
Fluid Outlet Size
Carbon and Stainless steel lowers:
1-1/2 in. npt(m)
Weight
Motor:
120 lb
Lower:
98 lb
Motor:
54.4 kg
Lower:
44.5 kg
Wetted parts
Carbon steel lowers:
Carbon steel; chrome, zinc and electric nickel plat-
ing; 304, 404, and 17-4 PH grades of stainless steel; silicone nitride;
tungsten carbide; ductile iron; acetal; PTFE; carbon-filled PTFE; UHM-
WPE; leather
Stainless steel lowers:
304, 329, and 17-4 PH grades of stainless steel;
silicone nitride; chrome plating; tungsten carbide; acetal, PTFE; car-
bon-filled PTFE; UHMWPE; leather
CALIFORNIA RESIDENTS
WARNING:
Cancer and reproductive harm – www.P65warnings.ca.gov.