Optional Cycle Detection Sensors
332089C
9
Optional Cycle Detection
Sensors
The sensors are magnetic reed switches and must be
connected to an electrical control package. The sensors
wires are #24 awg and have 9 foot (2.7 meters) flying
leads. An LED on the sensor illuminates to indicate a
change in state.
Suggested Sequence of Operation (See
page 18).
•
The Valve Inputs are listed in F
•
The Valve Outputs (supplied by others) consisting
of two power valves or one dual power valve [Sole-
noid-Close Spool Valve/RETract (Green Tube 1/4
in. OD) and Solenoid-Open Spool Valve/EXTend
(Yellow Tube 1/4 in.OD)]. Connect each Quick Dis-
connect (5/16-24 fitting) to respective power valve
port.
•
Other needed Input would include some type of
Start device (Foot Switch or Control Box) (supplied
by others)
1.
Home (Reload) Position
a.
Solenoid-Close Spool Valve/RETract is acti-
vated.
b.
Solenoid-Open Spool Valve/EXTend is deacti-
vated.
c.
PX-EXT and PX-CSV signal have been made.
d.
PX-RET and PX-OSV signal is not made.
e.
Metering Rod is Retracted.
2.
Shot Procedure
a.
Start device signal is made.
b.
Solenoid-Close Spool Valve/RETract is deacti-
vated.
c.
Solenoid-Open Spool Valve/EXTend is acti-
vated.
d.
PX-EXT and PX-CSV signal drops off.
e.
Spool shifts from the Reload Position to the Dis-
pense Position.
f.
PX-OSV signal is made.
g.
Metering Rod Extends downward (Dispensing
Material).
h.
PX-RET signal is made and Metering Rod is
down (Dispense Material Complete).
i.
Solenoid-Open Spool Valve/EXTend is deacti-
vated.
j.
Solenoid-Close Spool Valve/RETract is acti-
vated.
k.
PX-OSV signal drops Spool shifts from the Dis-
pense Position to the Reload Position and
Metering Rod Retracts upward (Reloading
Material).
l.
PX-CSV signal is made.
m. PX-EXT signal is made.
n.
Dispense Valve is ready for next Start device