background image

Warnings

3A9013A

3

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The 
exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. 
Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual 
where applicable.

WARNING

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. Paint or 
solvent flowing through the equipment can cause static sparking. To help prevent fire and explosion:

Use equipment only in well-ventilated area.

Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop 
cloths (potential static sparking). 

Ground all equipment in the work area. See Grounding instructions.

Never spray or flush solvent at high pressure.

Keep work area free of debris, including solvent, rags and gasoline.

Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes 
are present.

Use only grounded hoses.

Hold gun firmly to side of grounded pail when triggering into pail. Do not use pail liners unless they 
are anti-static or conductive.

Stop operation immediately if static sparking occurs or you feel a shock. Do not use equipment until 
you identify and correct the problem.

Keep a working fire extinguisher in the work area.

SKIN INJECTION HAZARD

High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like 
just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.

Do not spray without tip guard and trigger guard installed.

Engage trigger lock when not spraying.

Do not point gun at anyone or at any part of the body.

Do not put your hand over the spray tip.

Do not stop or deflect leaks with your hand, body, glove, or rag.

Follow the Pressure Relief Procedure when you stop spraying and before cleaning, checking, or 
servicing equipment. 

Tighten all fluid connections before operating the equipment.

Check hoses and couplings daily. Replace worn or damaged parts immediately.

Summary of Contents for 273319

Page 1: ...l coatings and adhesives For professional use only Dura Flo 900 220 cc Lower with 1 leather and 4 PTFE packings See page 2 for model information including maximum working pressure TI8343a Important Sa...

Page 2: ...Packing Repair Kit 25U661 11 Dimensions 12 Technical Specifications 13 California Proposition 65 13 Graco Standard Warranty 14 Graco Information 14 Related Manuals Models Manual in English Description...

Page 3: ...g or unplug power cords or turn power or light switches on or off when flammable fumes are present Use only grounded hoses Hold gun firmly to side of grounded pail when triggering into pail Do not use...

Page 4: ...ormation Route hoses and cables away from traffic areas sharp edges moving parts and hot surfaces Do not kink or over bend hoses or use hoses to pull equipment Keep children and animals away from work...

Page 5: ...Kits are available For the best results use all the new parts in the kit Kit parts are marked with an asterisk for example 3 These kits can also be used to convert the lower to different packing mater...

Page 6: ...d 1 and piston assembly will come out with these parts b Place the intake housing 16 in a vise Using a wrench on the cylinder 8 flats unscrew the cylinder The rod 1 and piston assembly will remain in...

Page 7: ...6 30 17 18 D Torque to 325 353 N m 240 260 ft lb Lubricate Torque to 190 217 N m 140 160 ft lb 1 2 3 1 2 3 1 TI8362a 1 9 15 1 9 10 E F 15 Torque to 271 298 N m 200 220 ft lb 4 4 4 4 P TI8361a Repair 3...

Page 8: ...cylinder 7 Install the seal 24 on the top of the cylinder 8 Lubricate the seal and the top threads of the cylinder 8 Place the outlet housing 7 in a vise see FIG 1 Slide the rod 1 into the housing app...

Page 9: ...71 298 N m 200 220 ft lb Lubricate Lips must face up Lips must face down Torque to 190 217 N m 140 160 ft lb Packing Repair Kit See Packing Repair Kit 25U661 page 14 2 1 TI8389a 1 2 7 T 24 8 P 24 16 1...

Page 10: ...Parts 10 3A9013A Parts TI8342b 2 7 1 24 8 18 17 30 16 24 15 10 9 50 See Repair Kits page 12 50 See Repair Kits page 12 20 51 52 1 1 1 Apply anti seize 123174...

Page 11: ...001 1 18 VALVE intake sst carbide seat 236588 1 20 PLUG pipe socket hd 3 8 npt sst 101748 1 23 TAG warning not shown 172479 1 24 SEAL cylinder PTFE 109499 2 30 SEAL intake valve PTFE 109499 1 50 PACKI...

Page 12: ...Dimensions 12 3A9013A Dimensions TI8343a B C A A mm in B C Weight kg lb 516 20 3 2 in npt f 1 in npt f 29 63...

Page 13: ...ed parts 304 316 440 and 17 4 PH grades of stainless steel tungsten carbide PTFE glass filled PTFE Packing materials See Repair Kits pages 12 17 Lower effective area Dura Flo 900 220 cc 1 40 in 2 9 cc...

Page 14: ...TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warranty shall be as set forth above The buyer agrees...