Installation
3A8502A
13
Pump Setup
1. Connect the supplied pump air regulator (AA) to the
air motor inlet (DA).
2. It is recommended to install a filter (AC) with the
required bleed-type master valve (AD) and air line
with a 3/8 in. (9.5 mm) ID minimum to the quick
disconnect air coupler provided.
3. Apply thread sealant to all non-swivel connections
and install the outlet fitting (not supplied) and
required fluid drain valve (AE) to the pump outlet.
on page 23 for more information on
the filter and valves.
4. Use the pump identification labels and bands
provided to identify the appropriate pump for your
material.
Install the Pump
1. Connect the bung adapter (AF) to the bung and
tighten securely.
2. Lubricate the o-ring on the outside of the bung
adapter (AF) and screw the bung adapter securely
into the bunghole (DB) of the drum.
3. Insert the pump (K) through the bung adapter (AF)
and lock the bung adapter clamp (BC) into place.