Setup
14
3A7031A
Sensor
Defines the low level input as a continuous monitoring
sensor.
•
Sensor Type: select the type of pressure sensor
output: 0-5 V, 1-5 V, 0-10 V, and 4-20 mA.
•
Threshold: the level that triggers the low level action.
Alert: the low level LED turns on. Output two turns
on.
Alarm: enters an alarm state and stops lubricating.
The low level LED flashes, and the screen shows an
alarm screen.
Note
: Disable the Low Level Alert or Alarm by
setting the threshold to zero.
Lock
The controller does not require a PIN to access the pro-
gramming features of the unit. However, an option for
adding PIN lock out is available.
Enable a Lock out PIN
Navigate to the menu item lock.
•
Lock: toggles on/off Lock out PIN protection.
•
PIN: enter a 4 digit code to unlock the device.
If a lockout PIN is enabled, a PIN must be used to
change settings.
Entering a PIN
When entering SETUP, the PIN entry screen appears
with the first digit highlighted. Use the arrow buttons to
enter the PIN.
After entering the last digit, press the RIGHT
ARROW button to accept the PIN.
If the PIN is correct, the device enters SETUP.
If the PIN is incorrect, the device returns to the main
screen.
Start Up
Navigate to the menu item start up.
•
Pre-lube: configures the GLC X to start a lubrication
event once powered on.
•
Delay: enables a delay between when the device is
powered on and when the controller resumes.
-
Delay Time: if applicable, configures the delay
time.
Output 2
Assign as alarm output or vent valve output.
System
In addition to date and time, enabling Bluetooth
®
and
disabling an audible alarm are found under this heading.
Date and Time
Navigate to the menu item time.
•
Date: defines today’s date.
•
Time: defines the current time. This clock runs on a
24 hour clock. (9 a.m. = 9, 2 p.m. = 14)
Additional Advanced Features
Advanced features are accessible through the mobile
app, gracoautolube, available for Android
®
and Apple
®
devices in the app store.
•
Generic alarm input: assign unused input to trigger
an alarm.
•
Pulsed output: pulses pump output during
lubrication event. Typically used with single stroke
pumps.