Operation
12
3A2988C
8.
Cycle the solvent flush ball valves on and off inde-
pendently several times to be sure both sides are
thoroughly flushed. Continue flushing until clean sol-
vent dispenses.
9.
Turn off solvent pump air supply.
10. Hold the metal part of the gun firmly to a grounded
metal pail with lid in place. Trigger gun until all fluid
pressure is relieved.
11. Engage trigger lock.
12. Close solvent inlet valves.
Dispensing and Spraying
1.
Close solvent inlet valves.
2.
Open mix manifold inlet ball valves.
3.
Ensure sprayer is in “spray” mode and push the
green START button.
4.
Disengage spray gun trigger lock.
5.
Hold the metal part of the gun firmly to a grounded
metal pail with a lid to avoid splashing. Trigger the
gun until mixed coating material is evident and
flushing fluid is gone.
6.
Proceed to spraying.