Setup and Operation
10
3A5083C
Pump Installation
Refer to your pump manual for pump installation. (See
on page 2.)
Verify that the fuses are removed before attaching pump
wires. See
on page 8.
Crimp included connectors on positive and negative
pump leads. Plug into controller wires as shown in F
Battery Installation
NOTE:
Batteries are provided by customer. See
on page 15 for recommended bat-
tery size.
1.
Ensure all fuses are removed. See
on page 8.
2.
Leave the battery terminal covers installed, if
included from the battery manufacturer, until the
battery is in place and ready to be wired.
3.
Carefully lift the battery up and into the control box.
4.
Connect the red battery cable from charge controller
Batt + to the positive battery terminal, and the black
battery cable from charge controller Batt - to the
negative battery terminal.
Controller Installation and
Operation
Refer to your controller manual for controller installation
and operation. (See
on page 2.)
To reduce the risk of fire and explosion, keep battery
terminal covers in place at all times, except for when
necessary during battery maintenance.
Unexpected activation could occur when power is
applied to the controller. Power to the controller
comes from the battery and solar panel. To reduce
the risk of serious injury, including skin injection, do
not wire the battery or solar panel until all fluid lines
are connected.
Battery acid could leak out if the system tips over. To
reduce the risk of injury, handle the system with care
and wear appropriate Personal Protective Equipment.