HMI Display Operation and Identification
36
3A7526B
Setup Screen 7 - De-pressurization
On the De-pressurization Setup Screen, press ‘F1’ or
select the
button to display the System Main
Screen. Press ‘F2’ or select the
button to return to
the previous screen. Press ‘F4’ or select the
button
to continue to the next screen.
The content and functions of this screen are as follows:
De-pressurization setup
•
Depressurization target: The operator may set the
depressurization target. The system will reduce the
pressure to the target volume automatically when
the job is finished.
NOTE:
Set different depressurization targets according
to different materials. For detailed information, please
contact your Graco distributor.
•
Max depressurization time: The operator may set a
maximum time in seconds for the system to perform
depressurization. If depressurization function
exceeds the set time, the system alarm will be
activated.
•
Depressurization rate: The operator may input a
value here to set the piston speed during
depressurization.
End job automatically
After this option is enabled, the operator must set the
maximum idle time for the system while performing a
job. After the set period passes without any operation,
the depressurization program will be automatically
executed and the current job ended.