Station Number
The current station number being displayed:
• 1–Maximum number of stations
Station Name
The alphanumeric name of the current station being displayed:
• 0–20 characters
Profile Number
The current agitator profile number being displayed:
• 1–2
Profile Name
The alphanumeric name of the agitator profile being displayed:
• 0–10 characters
NOTE:
NOTE:
NOTE: The system supports two profiles per agitator.
Minimum Speed
Enter the minimum speed setpoint for the agitator at the minimum tank level.
• 0–100%
Minimum Level
(L)
Enter the minimum tank level.
• 0–100%
Maximum
Speed
Enter the maximum speed set point for the agitator at the maximum tank level.
• 0–100%
Maximum Level
(H)
Enter the maximum tank level.
• 0–100%
On Time
Enter the On time when using agitator duty cycle. The agitator will cycle between the
specified On time and Off time.
• 0–59 minutes
Off Time
Enter the Off time when using agitator duty cycle. The agitator will cycle between the
specified On time and Off time.
• 0–59 minutes
Lock
Lock
Lock or
or
or Unlock
Unlock
Unlock Setup
Setup
Setup Screens
Screens
Screens
At the bottom of each Run screen, an icon indicates
whether access to that screen is locked or unlocked.
If the screen is locked and you press an onscreen
control to enter or change settings, the Enter
Password screen appears. Enter the password to
continue. See
• Press
to lock the screen.
• Press
and enter the password to unlock the
screen.