Technical Data
6
313347C
10. If air tube is not in downward position, continue to
thread manifold until it is.
11. Connect bracket (36) to retainer (16).
12. Pull trigger (11) and install set screw (39). Torque set
screw to 10 - 12 in-lb (1,1 - 1,4 N•m).
13. Install tip (28) and guard (29). Tighten securely.
14. Connect air hose.
Test Needle Installation
1.
Prime sprayer. See sprayer instruction manual.
2.
Trigger gun into bucket until fluid flows from gun.
3.
Release trigger (11). Fluid flow stops immediately.
4.
Set trigger lock (11a).
5.
Aim gun into bucket. Trigger gun. No fluid show flow.
6.
If gun fails tests of steps 3 and/or 5, relieve pressure
and disconnect hose. Readjust needle. Repeat tests.
Technical Data
Maximum inlet fluid pressure
3600 psi (24,8 MPa, 240 bar)
Maximum inlet air pressure
100 psi (0,7 MPa, 7 bar)
Air inlet
1/4 nps
Fluid inlet
1/4 nps
Sound levels per ISO 3744
Sound power level
less than 65.0 dB(A)
Sound pressure level
less than 65.0 dB(A)
Wetted parts
Bare spray gun
stainless steel, aluminum
Translated Manuals
Bulgarian- 313371
Dutch - 313351
German - 313355
Latvian - 313359
Portuguese - 313363
Slovenian - 313367
Croatian - 313348
Estonian - 313352
Greek - 313356
Lithuanian - 313360
Romanian - 313364
Spanish - 313368
Czech - 313349
Finnish - 313353
Hungarian - 313357
Norwegian - 313361
Russian - 313365
Swedish - 313369
Danish - 313350
French - 313354
Italian - 313358
Polish - 313362
Slovakian - 313366
Turkish - 313370