Pump
40
3A5082G
Fault/Warning Scenarios for Firmware Versions 5.06 and Later for
Non-DMS Models and 7.09 and later for DMS Models
Alarm Type
What it Looks Like
What it Indicates
Solution
Low Power
Warning
If there is a voltage drop at
the power source during
operation, the pump will go
into a low power warning
condition.
The unit will continue to
operate for a total of 15
minutes before going into a
Low Power Fault.
Also if the pump power
cycles on power up for a
minimum of 3 times, the
pump will display a low
power warning.
If the warning condition
clears itself, the warning is
cleared and the unit
continues operation.
Check voltage and
available current output at
the power source of the
pump.
Low Power
Fault
There is a low voltage
condition at the power
source.
Check voltage and
available current output at
the power source of the
pump.
Press and hold the
RESET button to clear
fault.