![Graco 24T918 Instruction Manual Download Page 67](http://html1.mh-extra.com/html/graco/24t918/24t918_instruction-manual_2252663067.webp)
Repair
333347F
67
Multi-Zone Low Power Temperature Control Module (MZLP)
Replace MZLP Fuse
MZLP Identification
Fuse Kits
1.
Turn main power switch OFF.
2.
Remove electrical enclosure front access door (10).
3.
Use a proper non-conductive fuse puller tool to
remove the blown fuse.
NOTE:
F1 and F2 are white ceramic and indicate 25A
on the barrel.
NOTE:
F3-F10 are clear glass and indicate 8A on the
barrel.
4.
Use a proper non-conductive fuse puller tool to
install the new fuse.
5.
Install electrical enclosure front access door (10).
Key
24V510
A
F1 and F2 fuses are physically larger than F3-F10
B
Blue sticker on relay
C
Marked 24V133
F
IG
. 46: MZLP ID and Fuse Locations
NOTICE
To prevent system damage, always use fast acting
fuses. Fast acting fuses are required for short-circuit
protection.
J1
J2
J3
J6
J5
J7
F10 F9
F8 F7
F6
F5
F4 F3
F2
F1
WLD
A
B
C
Fuse
Part
24V510 MZLP Fuses
F1, F2
250VAC, 25A, fast acting, white, 0.25 in x 1.2 in
F3-F10
250VAC, 8A, fast acting
Kit
MZLP
Description
24V289
24V510
Includes standard clear fuses.
24X480
Includes ceramic fuses used for
food industries.
NOTICE
Using an improper tool, such as screw drivers or
pliers may break glass on fuse.
NOTICE
Using an improper tool, such as screw drivers or
pliers may break glass on fuse.
Summary of Contents for 24T918
Page 16: ...Component Identification 16 333347F ...
Page 103: ...Accessories 333347F 103 ...
Page 129: ...Technical Data 333347F 129 ...