Installation
Installation
To prevent death or serious injury from electric shock
hazard, shutdown the system and disconnect main
power before installing kit.
1. Perform Shutdown procedure as described in the
system manual.
2. Disconnect main power so that no power is
coming into the power distribution box.
3. Remove one of the black caps from the electrical
box and a black cap from the DeviceNet bus bar.
4. Install the CAN splitter (Part No. 121807) into
the DeviceNet bus bar.
5. Bring the CAN cable from the CGM or DGM into
the power distribution box through the access
hole from step 3. Connect the CAN cable to the
splitter.
3A1974A