Fuse Replacement
3A1181B
21
Fuse Replacement
If the fuse is blown, check for:
•
Pinched or shorted wires
•
A defective motor
(see Spin Test, page 16)
•
A locked or frozen pump
Correct defective condition before replacing fuse.
Removal
1.
Relieve pressure, page 7
. Disconnect power cord
from outlet.
2.
Hi-Boy Models Only -
Disconnect high-pressure
hose at pump outlet
(see page 13)
.
3.
Remove two screws (4) and shroud (12)
(see illus-
tration, page 17)
.
4.
Remove fuse from control board.
Installation
1.
Install Fuse 119277 on control board.
2.
Install shroud (12) and two screws (4)
(see illustra-
tion, page 17)
.
3.
Hi-Boy Models Only -
Connect high-pressure hose
at pump outlet
(see page 14)
.
Replaceable Fuse
ti9134b
Summary of Contents for 24F561
Page 29: ...Notes 3A1181B 29 Notes...
Page 39: ...Notes 3A1181B 39 Notes...