Startup
313536U
13
Startup
1.
If your setup uses the optional shutoff valves,
rotate the handles to the “open” position.
2. Verify cables and hoses are correctly setup. See
section on page 10.
3. Check for excessive wear on cables and hoses.
Replace as necessary.
4. Close dump valve on hydraulic power pack.
5. Start power pack and verify hydraulic pressure is
1800 - 2500 psi.
6. Start chemical pumps.
7. Verify chemical pressure is in desired range.
8. Dispense a test shot into a waste container.
9. Clean any residual material from the tip of the gun.
F
IG
. 13: Shutoff Valves Positions
Open Position
Closed Position
ti18186a
Hydraulic pressure must not exceed the maximum
working pressure of 2500 psi (17 MPa, 172 bar).
Chemical pressure must not exceed the maximum
working pressure of 3000 psi (21 MPa, 207 bar).