Installation
16
311075ZAB
Installation
Location
•
Place the Reactor E-10 on a level surface.
•
Do not expose the Reactor E-10 to rain.
Grounding
Reactor E-10
: ground through the power cord.
Generator (if used):
follow your local code. Start and
stop generator with power cord(s) disconnected.
Spray gun:
grounded through the supplied fluid hoses,
connected to a properly grounded Reactor E-10. Do not
operate without at least one grounded fluid hose.
Object being sprayed:
follow local code.
Solvent pails used when flushing:
follow local code.
Use only conductive metal pails, placed on a grounded
surface. Do not place the pail on a nonconductive
surface, such as paper, plastic, or cardboard, which
interrupts grounding continuity.
To maintain grounding continuity when flushing or
relieving pressure:
hold metal part of the spray
gun/dispense valve firmly to the side of a grounded
metal pail, then trigger the gun.
Connect to a Power Source
1. Connect Reactor E-10 to the correct power source
for your model. See T
two power cords must be connected to two
separate, dedicated circuits. See F
NOTE
: Some models include cord adapters (55, 56) for
use outside North America. Connect the appropriate
adapter to the unit’s power cord before connecting to
your power source.
The equipment must be grounded to reduce the risk
of static sparking and electric shock. Electric or static
sparking can cause fumes to ignite or explode.
Improper grounding can cause electric shock.
Grounding provides an escape wire for the electric
current.
Improper wiring may cause electric shock or other
serious injury is work is not performed properly. All
electrical wiring must be done by a qualified
electrician and comply with all local codes and
regulations.