![Graco 245848 Instructions - Parts Manual Download Page 28](http://html1.mh-extra.com/html/graco/245848/245848_instructions-parts-manual_2251390028.webp)
Technical Data
28
309524V
Technical Data
The heater can be used in the following environmental conditions: indoor use, 99% maximum relative humidity, pollu-
tion degree 2, installation category II, maximum ambient temperature 140° F (60° C).
*
Main supply fluctuation not to exceed 10%.
Maximum Working Pressure
7250 psi (50 MPa, 500 bar)
Voltage / Wattage / Current*
See
, page 2
Fluid Passage Area
182 in.
2
(117,419 mm
2
)
Fluid Passage Diameter
0.435 in. (11.1 mm)
Fluid Passage Length
133 in. (3383 mm)
Thermometer Range
64–250°F (18–121°C)
Wetted Parts
Stainless Steel
Temperature Operating Range
84–219°F (29–104°C)
Weight
39 lb. (17.6 Kg)
94.16
68.39
57.70
50.68
42.23
34.96
30.26
26.64
54.14
39.32
33.18
29.14
24.28
20.10
17.40
15.32
0
10
20
30
40
50
60
70
80
90
100
0
0.5
1
1.5
2
2.5
3
3.5
4000W
2300W
Maximum Temperature Rise vs. Flow Rate
4000 watt VISCON HP heater, Test Fluid: 10w Hydraulic Oil
2300 watt VISCON HP heater, Test Fluid: 10w Hydraulic Oil
NOTE
: Line shows continuous operation of 1 heater.
Use additional heaters if necessary.
Maxim
um
T
emperature
Rise
(°F)
Flow Rate (GPM)