Recirculation Setting
30
310665E
Recirculation Setting
Fluid can be circulated up to the mix manifold with the
addition of Graco’s Circulation Kit (included on heated
units). Consult your distributor.
To set the Xtreme Mix 185 to circulate:
To terminate circulation,
press
.
To begin circulating again,
press
.
To begin spraying,
turn function knob to
, reset
system to desired ratio, and adjust pump to spray pres-
sure.
During recirculation only the pump runs; A and B
dispense valves do not operate. Material pumped
in recirculation mode is not counted by the total-
izer.
1.
Decrease the pump air pressure supply to the mini-
mum required to maintain the desired circulation vol-
ume.
2.
Turn function knob to
.
3.
Press .
CAUTION
Be sure recirculation valve does not leak material
back to fluid supply while spraying.