background image

INSTRUCTIONS–PARTS LIST

308–022

This manual contains IMPORTANT

WARNINGS AND INSTRUCTIONS

READ AND RETAIN FOR REFERENCE

Rev. A

FLUID FITTING SEAT

Part No. 223–440

Replacement seat for Model 3500

 Series

Electrostatic Air Spray Gun.

Fluid Fitting Seat

Spray gun not included.

WARNING

Pressure Relief Procedure

To reduce the risk of serious bodily injury, including
splashing in the eyes or on the skin, injury from moving
parts or electric shock,  follow this procedure before in-
stalling the seat.

1.

Turn the ES On–Off valve lever to OFF.

2.

Turn off the air and fluid supply to the gun.

3.

Trigger the gun into a grounded metal waste con-
tainer to relieve air and fluid pressure.

4.

Open the pump drain valve, having a waste con-
tainer ready to catch the drainage.

5.

Leave the pump drain valve open until you are
ready to spray again.

6.

Remove the fluid supply hose to the gun.

GRACO INC.   P.O. BOX 1441  MINNEAPOLIS, MN  55440–1441

COPYRIGHT 1989 GRACO INC.