Installation
6
306556T
Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever
you see this symbol.
1.
Close the supply pump’s bleed-type master air valve
(required in this system) (F
. 2).
2.
Open the air supply ball valve (F
. 2). The handle
will be in line with the valve body.
3.
Hold a metal part of the grease dispensing valve
firmly to a grounded metal waste container and
open the dispensing valve until the pressure is fully
relieved.
4.
If you suspect the dispense valve tip or hose is
clogged, or that pressure has not been fully relieved:
a.
VERY SLOWLY loosen the hose end coupling to
relieve pressure gradually.
b.
Loosen the nut or the coupling completely.
c.
Clear the obstruction in the hose or dispense
valve tip.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing
fluid and moving parts, follow the Pressure Relief
Procedure when you stop dispensing and before
cleaning, checking, or servicing the equipment.