Pressure Relief Procedure
6
311990F
Pressure Relief Procedure
Follow this
Pressure Relief Procedure
whenever you
are instructed to relieve pressure, stop spraying, check or
service equipment or install or clean spray tip.
1.
Turn OFF power and turn pressure control to lowest
pressure setting.
2.
Hold gun against side of grounded metal flushing
pail. Trigger gun to relieve pressure.
3.
Turn prime valve down.
If you suspect the spray tip or hose is clogged or that
pressure has not been fully relieved after following the
steps above, VERY SLOWLY loosen tip guard retaining
nut or hose end coupling to relieve pressure gradually,
then loosen completely. Clear hose or tip obstruction.
4.
Engage trigger safety lock on gun if unit is being
shut down or left unattended.
ti8324a
ti9035a
ti8326a