![Graco 16W119 Operation Download Page 18](http://html1.mh-extra.com/html/graco/16w119/16w119_operation_2251993018.webp)
Shutdown and Cleaning
18
332643B
Shutdown and Cleaning
Pail Flushing
•
For short term shutdown periods (overnight to two
days) refer to Short Term Storage, page 23.
•
For flushing after spraying oil-based coatings, use
compatible oil-based flushing fluid or mineral spirits.
Read Priming and Flushing Storage Fluid, page 12.
•
For flushing after spraying water-based coatings,
use water. Read Priming and Flushing Storage
Fluid, page 12 or Power Flush, page 20.
1.
Relieve pressure
, page 11.
2.
Remove tip and guard assembly from gun and place
in flushing fluid.
3.
Place empty waste and water or solvent pails side
by side.
4.
Lift suction tube and prime tube from paint pail. Let
them drain into paint pail for a while.
5.
Separate prime tube (smaller) from suction tube
(larger).
6.
Place prime tube in waste pail.
7.
Submerge suction tube in water or flushing solvent.
8.
Turn pressure control knob to the Prime/Clean set-
ting.
9.
Turn power switch ON.
10. Flush until approximately 1/3 of the flushing fluid is
emptied from the pail.
11. Turn power switch OFF.
ti9726a
WASTE
WATER or
SOLVENT
ti2039a
ti14962a
WASTE
ti14963a
WATER or
SOLVENT
ti12940a
ti5580a
ti2018a
Summary of Contents for 16W119