m908 User Manual, Rev. G
◦
Turn the VOLUME encoder to select between the available EQ parameters.
◦
Click the VOLUME encoder to edit the parameters.
◦
Click the VOLUME encoder again to enter the new value and return to the EQ
parameter select mode.
◦
Turn the VOLUME encoder to select the ► symbol and click to exit and return to EQ
band select mode.
◦
Turn the VOLUME encoder to select the EXIT bar on the right side of the screen to
exit EQ and return to
channel setup.
6.3.11
Monitor Control setup
Push the SETUP switch then press-hold the VOLUME encoder to enter Monitor Control setup
screen.
This screen contains the following a list of setup parameters that can be highlighted by turning
the VOLUME encoder knob.
NOTE: Headphone related monitor parameters are hidden if Headphone are disabled in the
current workflow. The available parameters are:
•
level control mode
Sets the step size for the VOLUME control encoder. Options are
<standard, course/fine>. In standard mode the VOLUME control adjusts the volume in
0.5dB steps with an accelleration curve that increases the step size the faster the control is
rotated. In <course/fine> mode the VOLUME control adjusts the volume in 4.5dB steps
for course adjustment. Pushing while turning the VOLUME encoder switches to fine
mode and changes the volume in 0.5dB steps.
•
speaker level disp mode
Sets the speaker level display mode. Options are <standard,
reference>
.
Page 91 of 135
Illustration 84: Setup Monitor Screen