m908 User Manual, Rev. G
◦
R = R + (–3 dB x C) + (–3 dB x RMS)
For downmix templates that have stereo output the Center channel summing level can be set
to the following values:
Center Downmix
Level
+3.0dB (1.414)
+1.5dB (1.189)
0dB (1.000)
-1.5dB (0.841)
-3.0dB (0.707) default
-4.5dB (0.596)
-6.0dB (0.500)
For downmix templates that have stereo output the surround channel summing level can be set
to the following values: Note: ProLogic II surround channel summing level is not adjustable.
Surround Downmix
Level
-1.5dB (0.841)
-3.0dB (0.707) default
-4.5dB (0.596)
-6.0dB (0.500)
section of this manual for configurations details.
5.20 Headphone Source Select
The Headphones, if enabled in the Workflow Setup, can be sourced from several signal
sources. For normal monitoring of what is being played in the Control Room, the headphones can
be sourced from the CR Left and Right channels. If a surround source is being monitored in the
Control Room then the headphones can be sourced from a separated downmixer that will output
a stereo version of surround signal. As well, the headphones can be assigned to a Cue path. This
allows the headphone amplifier to be used for Cue monitoring if an external headphone amplifier
Page 45 of 135