background image

IMPORTANT SAFETY INFORMATION. SAVE THESE INSTRUCTIONS.

TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND THIS INSTRUCTIONAL 

MANUAL. THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING THE OPERATION 

AND INSTALLATION OF PRODUCT. PLEASE RETAIN FOR FUTURE REFERENCE.

PURE SINE WAVE INVERTER

USER MANUAL

WWW.GOWISEPOWER.COM

PS1007

PS1009

PS1008

PS2001

Summary of Contents for PS1007

Page 1: ...NJURY USER MUST READ AND UNDERSTAND THIS INSTRUCTIONAL MANUAL THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING THE OPERATION AND INSTALLATION OF PRODUCT PLEASE RETAIN FOR FUTURE REFERENCE PURE SIN...

Page 2: ...ducts The package should contain the following 1 1 Inverter 2 2 Red and Black DC Terminal Covers 3 3 Remote 4 4 15 Ft Cable 5 5 Mounting Screws 6 6 User Manual Contact Our Customer Care Team 855 233 9...

Page 3: ...ions Personal Safety Precautions GeneralOverview Display Overview LCD Display Installation Preparing for Installation Inverter Unit Location Installation Guide Installation Materials Operation Mainten...

Page 4: ...notifiction During normal operation display and gauges are blue and green Anytime there are adverse conditions the LCD display and gauges will turn red based on the condition and the LCD display will...

Page 5: ...n it reaches a high temperature An alarm will go off first then the LCD will be red The inverter will shut down and auto restart Overload Protection The inverter will automatcially protect itself when...

Page 6: ...at surface 3 3 The remote cable should be plugged into inverter and the remote before being mounted NOTE The remote is optional and not required for inverter operation There is an ON OFF switch locate...

Page 7: ...xpose this unit to rain or snow Use of attachments not recommended or sold by GoWISE Power will void warranty and may result in the risk of fire electrical shock or personal injury To reduce the risk...

Page 8: ...EFORE SERVICING THE UNIT IN THE VICINITY OF THE BATTERY YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY 2 2 NEVER charge or invert power from a frozen battery 3 3 If necessary to remove a bat...

Page 9: ...ECTIONS IN AN ATMOSPHERE FREE OF EXPLOSIVE FUMES LOW VOLTAGE AVOID SERIOUS INJURY FROM ELECTRICAL BURNS AND SPARKS BEFORE PERFORMING ANY ELECTRICAL WORK DISCONNECT ANY DC POWER SUPPLY FROM UNIT CAUTIO...

Page 10: ...AC OUTLETS GROUND LUG TERMINAL POWER INPUT TERMINAL BLACK NEGATIVE POWER INPUT TERMINAL RED POSITIVE REMOTE USB COOLING FAN ON OFF SWITCH AC OUTLETS GROUND LUG TERMINAL POWER INPUT TERMINAL BLACK NEGA...

Page 11: ...e of the inverterstotal DC to AC conversion capability 0 to 100 The final LED turns red when the inverter loading more than full load 6 System Status The System Status LCD screen shows the status of t...

Page 12: ...ons Installation Precaution The power inverter should be mounted on a flat horizontal surface or a vertical surface In no case should the front or rear end caps be facing in an upward or downward posi...

Page 13: ...s 20cm of space at the DC end of the inverter for air flow 1 inch 2 5cm on each side and 3 inches 7 5cm at the AC end of the inverter For cooling the size of the space is not as important as the overa...

Page 14: ...IT WITHOUT THE EARTH CONNECTION ATTACHED The earth conductor is permitted to be 1 common size smaller than the DC positive conductor Example DC 2 AWG Earth 4 AWG 12 Volt DC Battery Source Batteries ca...

Page 15: ...ot longer than 6 feet Recommended cable sizes b Installing DC Safety ANL Fuse Install fuse in positive cable within 7 of battery See above table for recommended fuse DO NOT ATTEMPT CABLE TERMINATION B...

Page 16: ...ire a much higher startup current than their running current Since motors vary in their characteristics it is best to test the motor load on the inverter If the motor does not start or loses power the...

Page 17: ...istilled water if needed Finally check the battery voltage in accordance with the manufacturer s specifications Little maintenance is needed to keep the power inverter running properly To keep the uni...

Page 18: ...oceeding further 2 2 Note the conditions around the time the fault condition occurred Record the following details Battery voltage at the time of failure How many watts the inverter was putting out Ex...

Page 19: ...loose connections and tighten if needed Charge batteries to clear fault HI DC SHUTOFF Battery voltage is above 15 16 5 V and inverter output is shutoff Check for other DC inputs such as an over volta...

Page 20: ...oad Current 1A 12 5VDC Output Characteristics Continuous Output Power 1000W 1500W 2000W 3000W Surge Power 2000W 3000W 4000W 6000W Effiency MAX 90 Output Waveform Pure Sine Wave THD 3 Normal Load Outpu...

Page 21: ...21 NOTES...

Page 22: ...ny additional safety use or warnings included in the product packaging and manual This warranty only covers purchases within the 48 contiguous states of United States of America For purchases made out...

Page 23: ...ite your issue please provide the 4 items below 1 1 Copy of the invoice order information or gift receipt showing the date of purchase 2 2 Serial number usually found on a sticker located on the botto...

Page 24: ...structions carefully and thoroughly Please keep this manual for future reference Thank you for purchasing this GoWISE Power Pure Sine Wave Inverter www gowisepower com 855 233 9199 support gowiseusa c...

Reviews: