background image

 

 

 

 

User Manual

 

 

 

 

Quick-cleaning Neoflux® cleanflow magnet,  

series SECF 

 
 

 Suited for removal of ferromagnetic parts out of powders and granulates  

 Not suited for badly flowing (sticky) products 

 

 

 

 

 

 

The descriptions and pictures in this manual, used for explanation, may differ from your machine. 

We have enclosed the as-built drawing of the delivered machine. 

 

 

 
 

GOUDSMIT

 Magnetic Systems B.V. 

P.O. box 18 

5580 AA Waalre 

Petunialaan 19  

5582 HA Waalre 

The Netherlands 

Tel.:  

(+31) (0)40 221 32 83 

Internet: 

www.goudsmitmagnets.com

 

E-mail: 

[email protected]

 

Summary of Contents for Neoflux SECF Series

Page 1: ...sticky products The descriptions and pictures in this manual used for explanation may differ from your machine We have enclosed the as built drawing of the delivered machine GOUDSMIT Magnetic Systems...

Page 2: ...vision history Version Date Description 1 0 09 2004 First version of the English version of the user manual 1 1 10 2006 1 Revisions page added 2 All types of SECF clean flows gathered in this general...

Page 3: ...ogether with any relevant drawings and technical descriptions we supply remain our property It may not be duplicated or disclosed without our prior written permission The user manual can be ordered to...

Page 4: ...10 General 10 Danger of dust explosion 10 Danger of magnetic field 10 Separator specifications 12 Intended use user indications 12 Separator specifications 13 Working principle 14 Construction 15 Magn...

Page 5: ...truction manual are based on the available information at the time of delivery This is issued subject to later amendment We retain the right to amend or modify the construction and or model of our pro...

Page 6: ...rior written permission Parts are replaced with non OEM or non identical replacement parts Lubrication products other than those prescribed are used The equipment is used injudiciously incorrectly neg...

Page 7: ...entification plate On the device you will find an identification plate as pictured below Information on this plate is of great importance when service is required We therefore recommend that this plat...

Page 8: ...Da Db Equipment Protection Level EPL EPL Da Db Dc Suited for ATEX zone s 20 21 22 21 22 22 Da inside device Db outside device Ta Ambient temperature range only displayed when the range deviates from...

Page 9: ...sure that these are fitted by qualified personnel If the device is placed in storage or has a longer standstill make sure the device is emptied and cleaned The device must be grounded if a gasket is u...

Page 10: ...can accordingly be used in a dust zone 20 21 22 acc to ATEX workplace Directive 99 92 EC The Ex category is then described on the identification plate Make sure that the device complies to the correct...

Page 11: ...d within a radius of at least one metre Prohibited for people with pacemakers Credit cards chip cards computer disks tapes computer screens watches etc may be damaged or destroyed if they enter the ma...

Page 12: ...uited for product temperature range of 40 C up to 80 C or wider dependant on magnet type See product specifications for exact values The magnet is to be protected against higher temperatures than pres...

Page 13: ...ease contact us for more information Use in food product flows As standard the SECF is delivered with a 3 m ceramic blasted NON food finish On request this can be adapted so the Cleanflow can be used...

Page 14: ...duct stream will be attracted by the magnets and will cling onto the tubes while the cleaned material streams further The Fe parts will stay on the tubes until it will be removed manually This can be...

Page 15: ...ith bushes a magnet package in a surrounding SS tube or a magnet package in a surrounding SS tube in a SS extractor tube the extractor type The tube versions are waterproof If the magnet device is an...

Page 16: ...um non extractor type Cleanflow SECF Photo construction of Ferroxdure ferrite non extractor type Cleanflow SECF Fastener clamp Hatch opening Gasket Product channel Magnet bars Bottom flange Upper flan...

Page 17: ...e extractor tube unit on a clean surface 5 Wipe clean with a brush of soft cloth and or blow clean the extractor tubes not in the direction of or over the magnet bars 6 Clean the magnet bars and or in...

Page 18: ...uring lifting and transport Mount the flanges of the device tightly to the inlet and outlet flange of your product channel Improper alignment and loose assembly may cause leakage of raw product Ensure...

Page 19: ...our product flow before it passes the Cleanflow Advise place a sieve filter in front of the clean flow Also see chapter Maintenance Damage to the magnet bars and or damage caused by damaged bars is no...

Page 20: ...if applicable have been fitted correctly That all objects larger than 10mm are blocked from entering the product channel The device is thoroughly cleaned internally and externally The product does not...

Page 21: ...out Wear as a following of abrasive product can be reduced by coating the outside bars with for instance tungsten carbide Please contact GOUDSMIT magnetic systems for advice During maintenance and or...

Page 22: ...remedy Magnet does not separate ferromagnetic Fe particles out of the product stream or separates them badly Magnet bar is overloaded with Fe parts Clean the magnet more frequently Not attracted obje...

Page 23: ...ed by quoting the type number stated on the identification plate or on one of the drawing s added to this user manual in the added data sheet The spare parts are mostly wear parts such as The extracto...

Page 24: ...sensitive parts Dismantling scrapping On scrapping and or disposal of the device s parts separately take into account the different nature and dangers of the components magnets iron aluminium electri...