Operating Manual HG G-98830YA | English, Revision 02 | Date: 21.06.2021
43
Interfaces – Chapter 9
9.4 CAN
The internal Full CAN module is based on the CAN specification V2.0 Part B. Both
standard and extended frames can be sent. You can set the CAN parameters (bit tim
-
ing, identifier, standard/extended frames) via the system monitor (see 10 „Configu
ration of the System via the Service Interface“ on page 48).
Different CAN message objects can be output. You can configure whether telegrams
are output permanently with the adjustable update rate or only when a transponder
is in the field. In addition, remote operation can also be set. The objects are activated
by entering an address other than 0 in the CAN menu (see section 10.2.8 „Basic
C(A)N-Parameters“ on page 62).
9.4.1 CAN Message Object – Y-Identifier, Send Object
9.4.2 CAN Message Object – X-Identifier, Send Object
9.4.3 CAN Message Object – D-Identifier, Send Object
Table 16
Structure of the CAN Message Object – Y Identifier
Byte # Length Type
Meaning
1,2
2 Byte unsigned int
System status notes according to Table 9 on
page 37
3,4,5,6
4 Byte unsigned long
20 bit transponder code
(R/W transponder)
7,8
2 Byte signed int
Distance Y [mm]
Table 17
Structure of the CAN Message Object – X Identifier
Byte # Length Type
Meaning
1,2
2 Byte unsigned int
System status notes according to Table 9 on
page 37
3,4,5,6
4 Byte unsigned long
20 Bit transponder code
(R/W Transponder)
7,8
2 Byte signed int
Distance X [mm]
Table 18
Structure of the CAN Message Object – D Identifier
Byte # Length Type
Meaning
1,2
2 Byte unsigned int
Voltage generated by the transponder in the
Reference Antenna
3,4
2 Byte signed int
Voltage generated by the transponder in the
Positioning Antenna
5
1 Byte unsigned char
Number of code readings of the last tran
-
sponder crossing
6
1 Byte unsigned char
Operating voltage (see telegram description
in Table 8 on page 36)
7
1 Byte unsigned char
Operating current (see telegram description
in Table 8 on page 36)
8
1 Byte signed char
Operating temperature (see telegram
description in Table 8 on page 36)