Device Description HG G-98780-A | English, Revision 16 | Date: 15.07.2021
51
Appendix – Chapter 10
A set of data always starts with an “=“-character (hex 0x3d), followed by the accord
-
ingly selected parameters from the menu. The telegram is terminated with an 8 bit
check character (incl. start character). This check character is the result of ex-oring
all characters. The characters are transmitted without delay.
10.7.2 Data direction PLC -> antenna
Commands are transmitted in this direction upon request. Each command has to
start with an “=“-character (hex 0x3d). The format of the commands is described in
Table 10 „List of System Commands“ auf Seite 22. The telegram is terminated with
an 8 bit check character over all characters (incl. start character). The characters are
transmitted without delay. The characters have to be received within the parameter
-
izeable character delay time. Otherwise the telegram will be chopped.
10.8 GSD File (Antenna HG 98780XA/YA with Profibus)
The latest version of the GDS files can always be downloaded from our website.