Components and Operation
English, Revision 06, Date: 14.12.2016
23
Depending on the configuration of the master using the GSD files the corresponding
quantity of input bytes will be transmitted. Input bytes may have the values 6, 7, 8, 9,
11, 12, 14, 16.
4.2.5.2
Output Byte
Only the positive slope of the least significant bit of this byte is used for switching the
reference transponder on. Its status is indicated correspondingly in the system status
(refer to Table 6 on page 18).
4.2.6
Software update
If necessary, the antennas may be updated via the serial interface. Please refer to sec-
tion 5.3 on page 38.
4.3
Accessories (optional)
4.3.1
Serial/parallel Interface HG 06150-A
7
7
1 Byte
unsigned char
applied antenna voltage
[x 100 mV]
8
8
1 Byte
unsigned char
current consumption
[x 10 mA]
9
9
1 Byte
unsigned char
measured temperature within
antenna [
o
C]
12
10
2 Byte
signed int
Dummy entry
11
12
1 Byte
unsigned char
number of code readings
14
13
2 Byte
signed int
HiByte (LoByte)
voltage the transponder indu-
ced in the difference coil in
samples
14
LoByte (HiByte)
16
15
2 Byte
unsigned int
HiByte (LoByte)
voltage the transponder indu-
ced in the frame antenna in
samples
16
LoByte (HiByte)
*) = if
Order of Data Transfer
(see 5.2.2.6 on page 36) corresponds
Number of
Input Bytes
Byte #
Length
Type
Order of bytes
*)
Meaning
Table 13
Profibus Input Bytes (Section 2 of 2)