Device Description HG G-71912-A | English, Revision 03 | Date: 28.03.2018
37
Software – Chapter 6
6.2.2.4 P(a)rallel Interface
Figure 16
Menu P(a)rallel Interface
In this menu the characteristics of the parallel interface can be set. It is only important for
interpreter variant HG G-71912YA.
The duration of the data ready pulse DTR (
) can be modified using 1 ms steps. With DTR
Seup Time (
) the time from creating the parallel code to the output of the DTR code can
be determinded (see also appendix, chapter F „Timing-Diagramm of the parallel interface“
on page 51).
With
you can determine whether only one transponder with a new code generates a
DTR pulse (1) or if the same transponder can generate two pulses by crossing the detection
area and leaving it again (0).
With
all outputs can be set to 1 or 0 for test purposes. The outputs DTR and Posipuls will
be active for the set time. After leaving the monitor mode all outputs will be turned off again.
S:0020 D:+0022 Code: 000fffff Read: 114 E: 0120 N: 0 Ftx[Hz]:128010
DT(R)-Pulse Time [n*1ms]: 100
DTR-(S)etup Time [n*1ms]: 50
(1) DTR - Pulse per Code 0
(O)uttest
(Q)uit Menue