Device Description HG G-71910-C | English, Revision 03 | Date: 17.09.2019
45
Technical Data – Chapter 8
8
Technical Data
Table 45
Technical Data Antenna HG 71910-C
Antenna HG 71910-C
Casing
Dimensions see Figure 11 on page 17
Effective antenna area
140 x 70 mm (positioning range)
EMC
refer to Table 46 on page 46
Cable length
The maximum length of the connection cable
should not exceed 10 m!
Power supply
24 V ±10 %, approx. 500 mA
Operating temperature
0 to +50
o
C
Mechanical stability
5 g 11 ms / 2 g 10 to 55 Hz
Installation regulations
Protection class
IP 65 (Version HG G-71910VC: IP 40)
Connectors
see variant overview in Table 2 on page 17
Reading distance
30 to 70 mm
(distance transponder –> underside reading
antenna)
Nominal reading distance
50 mm
Positioning accuracy
±3 mm on the center axis
Repeat accuracy
2 mm
Max. pass- over speed
–
1 m/s with positioning
–
2 m/s without positioning
Programming time
approx. 30 ms
Serial interface
RS232 with 9600 or 19200, even parity, 1 stop bit,
procedure 3964R or transparent
Crossing pulse
24 V, 20 mA
CAN-Bus
(Version HG G-71910ZC)
According to ISO/DIS 11898 Identifier, Data rate,
Basic/Extended CAN; configurable via serial inter
-
face
Parallel output
(Version HG G-71910YC)
Data output: 15+1, 24 V, no current limit!