Device Description HG G-71910-C | English, Revision 03 | Date: 17.09.2019
13
Installation / Commissioning – Chapter 4
The following diagrams show examples of logged system data:
Figure 5
Diagram: Commissioning Protocol / insignificant interference level; shown is the sum
voltage over the travelled distance
The above diagram shows the sum voltage (in units) over the travelled distance. The
noise is in this case approx. 50 units, the transponder signal approx. 950 units. The
transponder decoding is perfect, as also shown in the following diagram:
Figure 6
Diagram: Commissioning Protocol / undisturbed Transponder decoding
During each transponder crossing, the sum voltage increases initially. Once the
threshold
Threshold for Decoding
has been exceeded, the bit
TRANS_IN_FIELD
is set. Following 4 x 8 ms (= 4 data points) the transponder
code is decoded. The duration depends on the setting for
Number of Equal
Codes
within the menu
Time & Code
. In this example, this parameter is = 2, i. e.
the newly received code is compared to two codes which were already received.
Once the center of the antenna has been crossed, the
POSI Pulse
is generated.
Its duration is adjustable. The bits
TRANS_IN_FIELD
and
CODE_OK
are deleted,
whenever the sum voltage falls below the value for
Threshold for Decod
-
ing
. In the shown example there is spare time of 6 x 8 ms for the generation of the
POSI-Pulse
. The velocity of crossing was 1.1 m/s (180 mm antenna length / (20
x 8 ms)
Low Interference Level
Undisturbed Transponder Decoding